ID : 1011

List of I/O Commands

The table below lists I/O commands.

I/O commands written in the following table are available only when the I/O allocation mode is the standard allocation. If the I/O allocation mode is Mini I/O-dedicated mode, refer to "List of I/O Commands" in the "[Mini I/O-dedicated mode] Types and Functions of System Input Signals". If the I/O allocation mode is the RC3 compatible mode, refer to "[RC3 Compatible Mode] Types and Functions of System Input Signals."

All I/O commands must be used with I/O port No.515 "Strobe Signal (Input)."

If either the I/O port No.770 "Robot Error (Output)" or the I/O port No.776 "Robot Warning (Output)" occurs, any I/O commands other than "Clear Robot Error" cannot be used.

Command area Data area 1 Data area 2 Status area
0001
Program Operation

00000001 Program reset start

Program number

-

00000010 Program start

Program number

-

00000100 Continue start

*

-

00010000 Step stop

Program number

-

00100000 Instantaneous stop

Program number

-
01000000 Reset Program number -
10000000 Activation of Supervisory Tasks Program No.( 0xffff activates all supervisory tasks of root, 0xfffe activates all supervisory tasks) -
10000001 Deactivation of Supervisory Tasks Program No. (0xffff deactivates all supervisory tasks) -
0010
External Speed and Acceleration Setting

00000001 Speed setting

Set speed value

-

00000010 Acceleration setting

Set acceleration value

-

00000100 Deceleration setting Set deceleration value -
0100
Error Read
- - Error number
0101
Type I Variable Write
Type I variable number Set variable value (lower 16 bits) -
0110
Type I Variable Read
Type I variable number - Variable value (lower 16 bits)
0111
Mode Switching

00000001 Motor ON, CAL execution

- -

00000010 External speed 100

- -

10000000 External mode switching

10000011 Execution of all above

(Motor ON -> CAL -> SP100 -> External)

- -
1000
Clear Robot Error
- - -
1001
I/O Write
Set I/O value First internal I/O port address -
1010
I/O Read
- First internal I/O port address I/O

*In execution of Continue Start command, program numbers will be ignored.

Order of Bit String

For command area, the data area 1 and the data area 2, each figure on bit strings apply to bit 0, bit 1, and bit 2 in order from the right.

See "Command and Data Areas" for the meanings of 0 and 1.
For about bits and ports allocation, refer to standard assignments section on the user's manual of each extension board.

Example: Program Execution

To execute PRO6, specify [0001 Program Operation], [00000010 Program start], and then [Program number =6].
"6" is expressed by binary number of sixteen figures as "0000000000000110".

The table below shows the correspondence between bit strings and areas.

Bit Command area Data area 1

Data area 2

Bit 0 1 0 0
Bit 1 0 1 1
Bit 2 0 0 1
Bit 3 0 0 0
Bit 4 Unused 0 0
Bit 5 0 0
Bit 6 0 0
Bit 7 0 0
Bit 8 Unused 0
Bit 9 0
Bit 10 0
Bit 11 0
Bit 12 0
Bit 13 0
Bit 14 0
Bit 15 0

Based on the table above, each port turns ON (short) /OFF (open) as shown below. Port number in the table below shows the number of DeviceNet.

Port No.
(example)
Application ON (short) /OFF (open)
520 Data area 1 Bit 0 OFF
521 Data area 1 Bit 1 ON
522 Data area 1 Bit 2 OFF
523 Data area 1 Bit 3 OFF
524 Data area 1 Bit 4 OFF
525 Data area 1 Bit 5 OFF
526 Data area 1 Bit 6 OFF
527 Data area 1 Bit 7 OFF
528 Data area 2 Bit 0 OFF
529 Data area 2 Bit 1 ON
530 Data area 2 Bit 2 ON
531 Data area 2 Bit 3 OFF
532 Data area 2 Bit 4 OFF
533 Data area 2 Bit 5 OFF
534 Data area 2 Bit 6 OFF
535 Data area 2 Bit 7 OFF
536 Data area 2 Bit 8 OFF
537 Data area 2 Bit 9 OFF
538 Data area 2 Bit 10 OFF
539 Data area 2 Bit 11 OFF
540 Data area 2 Bit 12 OFF
541 Data area 2 Bit 13 OFF
542 Data area 2 Bit 14 OFF
543 Data area 2 Bit 15 OFF
544 Command area Bit 0 ON
545 Command area Bit 1 OFF
546 Command area Bit 2 OFF
547 Command area Bit 3 OFF