<< Prev        Next >>

ID : 5188

Output Data (RC3 Compatible Allocation)

Port No. Signal name
768 -
769 Robot Running
770 Robot Error
771 Auto Mode
772 External Mode
773 Program Start Reset
774 -
775 -
776 Robot Power ON Completed
777 Servo ON
778 CAL Completed
779 Teaching ON
780 1 Cycle End
781 Battery Warning
782 Robot Warning
783 Continue Start Permission
784 Error in the units place, bit 0
785 Error in the units place, bit 1
786 Error in the units place, bit 2
787 Error in the units place, bit 3
788 Error in the tens place, bit 0
789 Error in the tens place, bit 1
790 Error in the tens place, bit 2
791 Error in the tens place, bit 3
792 Error in the hundreds place, bit 0
793 Error in the hundreds place, bit 1
794 Error in the hundreds place, bit 2
795 Error in the hundreds place, bit 3
796 -
797 -
798 -
799 -
800 User output (*)
:
1023
7872 User output (*)
:
11647

 

* : The range of available I/O port numbers differs depending on the output size setting. As a default setting, the user output ranges from 800 through 1023 (output size: 32). If the output size is 33 or over, user outputs are allocated to 800-1023, 7872-11647. For example, if the output size is 33, the user outputs are allocated to 800-1023, 7872-7879.

 

ID : 5188

<< Prev        Next >>