[Compatible Mode] Types and Functions of System Input Signals
The table below lists the system input signals to be used in compatible mode.
| Application | Signal name | Function |
|---|---|---|
|
Start-up |
Motor Power ON + Operation Preparation Start | Turns ON the power to the motor. |
| CAL Execution + Operation Preparation Start |
This signal is for the compatible mode-use. Switching CAL execution causes no effect on operations because RC8 controls no robot that requires CAL. |
|
| SP100 + Operation Preparation Start | Sets the speed to 100%. | |
| Switch Ext Mode + Operation Preparation Start | Switches the mode to external mode. | |
| Program Reset + Operation Preparation Start | Initializes all programs on halt. Starting a program after initialization will execute the program from the beginning. | |
| Program No. Select + Program Start | Executes a specified program. | |
| Program execution | Program Reset + Program No. Select + Program Start | Cancels the current program and starts executing a specified program from the beginning. |
|
Stop |
Step Stop | Step-stops all programs by opening signals. |
| Instantaneous Stop | Instantaneously stops all programs by opening signals. | |
| Error clear | Clear Robot Error + Operation Preparation Start | Clears an error. |
| Program interrupt | Interrupt Skip | Interrupts the execution of the current step and starts the next step. |
| Continue start | Continue Start + Program Start | Executes continue start. |
- Two or more signal names listed in the signal name field indicate that they should be used in combination.
- System output signals are checked every 8 ms.