Specification of Controller
The table below shows specification of RC8 type robot controller.
| Term | Specification | |
|---|---|---|
| Applicable robots |
VM-6083 / VM-60B1
VS-6556 / VS-6577 VS050 / VS060 / VS068 / VS087 VP-6242 / VP-5243 HM series / HS series XR series |
|
| Type | RC8-****-****-**-*** | |
| Number of axes controlled |
Robot: 4 to 6 axes Extended-joint: 2 to 4 axes (optional) |
|
| Control method | PTP, CP 3-dimensional linier, 3-dimensional arc (PTP control only for additional axes) | |
| Drive method | All axes all digital AC servo | |
| Language in use | DENSO Robotics language (PacScript) | |
| Memory capacity | User area Variable area: 1.75 Mbyte (32,766 points equivalent), file area: 400 Mbyte (5,000 steps x 256 files) | |
| Teaching method |
|
|
|
External signal (I/O, etc.) |
Mini I/O | Input : 16 points + Safety circuit signal Output : 16 points + Safety circuit signal |
| Hand I/O | Input : 8 points Output : 8 points |
|
Safety I/O |
Input and output signal is concentrated in Mini I/O connector |
|
| Parallel I/O board (optional) (*1) |
Expansion slot : PCI Input : 40 points Output : 48 points |
|
| CC-Link remote device board (optional) (*1) |
Expansion slot : PCI Express
Input: Up to 8192 points Output: Up to 8192 points
|
|
| DeviceNet slave board (optional) (*1) |
Expansion slot : PCI Express
Input : Up to 256 points Output : Up to 256 points |
|
| DeviceNet master board (optional) (*1) |
Expansion slot : PCI Express
Input : 1024 points Output : 1024 points |
|
| EtherNet/IP Adapter board (optional) (*1) |
Expansion slot : PCI Express Input: Up to 4032 points Output: Up to 4032 points |
|
| PROFIBUS slave board (optional) (*1) |
Expansion slot : PCI Express
Input : Up to 256 points Output : Up to 256 points |
|
| PROFINET IO Device board (optional) |
Expansion slot : PCI Express
Input: Up to 8192 points Output: Up to 8192 points |
|
| EtherCAT slave board (optional) |
Expansion slot : PCI Express Input: Up to 2048 points Output: Up to 2048 points |
|
| RS232C expansion board (optional, not supplied) |
DENSO supplies software only and board is not supplied. | |
| External communication | RS232C | 1 line |
| Ethernet | 1 line (GbE: Gigabit Ethernet) | |
| USB | 2 lines | |
| VGA optional | 1 line | |
|
Electric gripper control board (optional) ( *1) |
Expansion slot : PCI | |
| Expansion slot |
|
|
| Self diagnosis function | Overrun, servo error, memory error, input error, short circuit detection (user wiring part), etc. | |
| Timer function | 0.02 to 10 sec (1/60 sec step) | |
| Error display |
|
|
| Cable |
Motor & encoder cable for RC8 (optional) |
2m, 4m, 6m, 12m, 20m
Note) VP, XR are standard version only |
|
I/O cable (optional) |
8m, 15m (for Mini I/O, for Hand I/O, for expansion parallel I/O) |
|
| RC8 power cable | 5 m | |
|
For RC8 Extended-joint motor cable (optional) |
2m, 4m, 6m, 12m (standard version) |
|
|
For RC8 Extended-joint encoder cable (optional) |
1m, 2m, 4m, 6m, 12m (standard version) |
|
|
External operation device |
Teach pendant (optional) |
4m, 8m, 12m |
|
Mini-pendant (optional) |
4m, 8m, 12m | |
|
Pendant extension cable (optional) |
4m, 8m | |
|
Emergency stop box (optional) |
Available | |
| Environmental condition (in motion) | Temperature 0 to 40 degree C, humidity 90 % RH or less (no condensation allowed) | |
| Power supply | VM 3-phase AC200V -15 % to AC240V +10 %, 47 to 63 Hz, +3.3 kVA |
|
| VS-6556/6577 3-phase AC200V -15 % to AC240V +10 %, 47 to 63 Hz, 1.8 kVA single phase AC230V -10 % to AC240V +10 %, 47 to 63 Hz, 1.8 kVA |
||
| VS-050/060 3-phase AC200V -15 % to AC240V +10 %, 47 to 63 Hz, 1.15 kVA single phase AC230V -10 % to AC240V +10 %, 47 to 63 Hz, 1.15 kVA |
||
| VS-068/087 3-phase AC200V -15 % to AC240V +10 %, 47 to 63 Hz, 2.78 kVA single phase AC230V -10 % to AC240V +10 %, 47 to 63 Hz, 2.78 kVA |
||
| VP 3-phase AC200V -15 % to AC240V +10 %, 47 to 63 Hz, 1.0 kVA single phase AC230V -10 % to AC240V +10 %, 47 to 63 Hz, 1.0 kVA 100V version AC100V -5 % to AC110V +10 %, 47 to 63 Hz, 1.0 kVA (*2) |
||
| HM series 3-phase AC200V -15 % to AC240V +10 %, 47 to 63 Hz, 2.45 kVA single phase AC230V -10 % to AC240V +10 %, 47 to 63 Hz, 2.45 kVA |
||
| HS series 3-phase AC200V -15 % to AC240V +10 %, 47 to 63 Hz, 1.8 kVA single phase AC230V -10 % to AC240V +10 %, 47 to 63 Hz, 1.8 kVA |
||
|
XR series 3-phase AC200V -15 % to AC240V +10 %, 47 to 63 Hz, 1.85 kVA single phase AC230V -10 % to AC240V +10 %, 47 to 63 Hz, 1.85 kVA |
||
| I/O power supply | Use external power supply | Supply DC24V +/-10 % from outside |
| Use internal power supply | Supply DC24V +/-10 % from inside controller | |
| Safety performance (*3) | Structure : Category 4
Performance Level : e MTTFd : 100 years DCavg : 99% PFHd : 9.89×10-8 * Please specify the safety-I/O-less version in the case that safety I/O mounted on the standard version is not necessary |
|
| Stop category | Category1
(except Safety-I/O-less type.) (See IEC60204-1 for details of stop category) |
|
| Protect grade |
IP20 IP54 by using protective box (optional) |
|
| Stand for vertical setup | Note) Set right side (power connector side) down | |
| External dimension |
Standard : W 440.5 x D 299.6 x H 96.6 [mm] 12.8 L UL : W 440.5 x D 400 x H 130 [mm] 17.8 L |
|
| Weight |
Standard : approximately 12 kg UL : approximately 18 kg |
|
*1: Expansion boards used in the RC7 robot controller cannot be used.
*2: If the power supply can be dropped 95V or less, such as in the heavily loaded facilities, using a transformer describes below is recommended. However, operation with 85V or lower voltage is not guaranteed.
- Transformer specification
-
Input voltage : 1Ph 100V
Output voltage : 1Ph 200V
Capacity : 1kVA
*3 : This safety performance is determined for the robot stop functions; such as an emergency stop, enable auto, protective stop and deadman switch.
However, customer-prepared input devices (an emergency stop, enable auto, a switch connecting to the protective stop, etc.) are not included in the safety performance calculation
- Calculation conditions
-
· This calculation is based on ISO 13849-1:2006.
· Expected operation time; 10 years (20 days / month)
· Start/ Stop (Motor ON/OFF) switching is expected 50 times a day.
· Expected operation time of the enable (deadman) switch ; 15200 times.