<< Prev        Next >>

Specification of Controller

The table below shows specification of RC8 type robot controller.

Term Specification
Applicable robots VM-6083 / VM-60B1

VS-6556 / VS-6577

VS050 / VS060 / VS068 / VS087

VP-6242 / VP-5243

HM series / HS series

XR series

Type RC8-****-****-**-***
Number of axes controlled Robot: 4 to 6 axes
Extended-joint: 2 to 4 axes (optional)
Control method PTP, CP 3-dimensional linier, 3-dimensional arc (PTP control only for additional axes)
Drive method All axes all digital AC servo
Language in use DENSO Robotics language (PacScript)
Memory capacity User area Variable area: 1.75 Mbyte (32,766 points equivalent), file area: 400 Mbyte (5,000 steps x 256 files)
Teaching method
  1. Direct teaching...Horizontal articulated model only
  2. Remote teaching
  3. Numerical entry (MDI)
External signal
(I/O, etc.)
Mini I/O

Input : 16 points + Safety circuit signal

Output : 16 points + Safety circuit signal

Hand I/O

Input : 8 points

Output : 8 points

Safety I/O

Input and output signal is concentrated in Mini I/O connector

Parallel I/O board
(optional) (*1)

Expansion slot : PCI

Input : 40 points

Output : 48 points

CC-Link remote device board
(optional) (*1)
Expansion slot : PCI Express

Input: Up to 8192 points

Output: Up to 8192 points

Remote register

Input: Up to 2048 words

Output: Up to 2048 words

DeviceNet slave board
(optional) (*1)
Expansion slot : PCI Express

Input : Up to 256 points

Output : Up to 256 points

DeviceNet master board
(optional) (*1)
Expansion slot : PCI Express

Input : 1024 points

Output : 1024 points

EtherNet/IP Adapter board
(optional) (*1)

Expansion slot : PCI Express

Input: Up to 4032 points

Output: Up to 4032 points

PROFIBUS slave board
(optional) (*1)
Expansion slot : PCI Express

Input : Up to 256 points

Output : Up to 256 points

PROFINET IO Device board
(optional)
Expansion slot : PCI Express

Input: Up to 8192 points

Output: Up to 8192 points

EtherCAT slave board
(optional)

Expansion slot : PCI Express

Input: Up to 2048 points

Output: Up to 2048 points

RS232C expansion board
(optional, not supplied)
DENSO supplies software only and board is not supplied.
External communication RS232C 1 line
Ethernet 1 line (GbE: Gigabit Ethernet)
USB 2 lines
VGA optional 1 line
Electric gripper control board
(optional) ( *1)
Expansion slot : PCI
Expansion slot
  • PCI 1 slot
  • PCI Express 1 slot
Self diagnosis function Overrun, servo error, memory error, input error, short circuit detection (user wiring part), etc.
Timer function 0.02 to 10 sec (1/60 sec step)
Error display
  • External error output
  • Display error code on mini-pendant (optional)
  • Display error message, resume method on teach pendant (optional)
Cable Motor & encoder cable for RC8
(optional)
2m, 4m, 6m, 12m, 20m

Note) VP, XR are standard version only
Note) VM, HS, HM are standard / splash-proof version
Note) VS is dedicated version
Note) Motor connector x 3, encoder connector x 1
Note) The 20m cable is not available for the UL-listed robot unit.

I/O cable
(optional)
8m, 15m
(for Mini I/O, for Hand I/O, for expansion parallel I/O)
RC8 power cable 5 m
For RC8 Extended-joint
motor cable
(optional)
2m, 4m, 6m, 12m
(standard version)
For RC8 Extended-joint
encoder cable
(optional)
1m, 2m, 4m, 6m, 12m
(standard version)
External operation
device
Teach pendant
(optional)
4m, 8m, 12m
Mini-pendant
(optional)
4m, 8m, 12m
Pendant extension cable
(optional)
4m, 8m
Emergency stop box
(optional)
Available
Environmental condition (in motion) Temperature 0 to 40 degree C, humidity 90 % RH or less (no condensation allowed)
Power supply VM
3-phase AC200V -15 % to AC240V +10 %, 47 to 63 Hz, +3.3 kVA
VS-6556/6577
3-phase AC200V -15 % to AC240V +10 %, 47 to 63 Hz, 1.8 kVA
single phase AC230V -10 % to AC240V +10 %, 47 to 63 Hz, 1.8 kVA
VS-050/060
3-phase AC200V -15 % to AC240V +10 %, 47 to 63 Hz, 1.15 kVA
single phase AC230V -10 % to AC240V +10 %, 47 to 63 Hz, 1.15 kVA
VS-068/087
3-phase AC200V -15 % to AC240V +10 %, 47 to 63 Hz, 2.78 kVA
single phase AC230V -10 % to AC240V +10 %, 47 to 63 Hz, 2.78 kVA
VP
3-phase AC200V -15 % to AC240V +10 %, 47 to 63 Hz, 1.0 kVA
single phase AC230V -10 % to AC240V +10 %, 47 to 63 Hz, 1.0 kVA

100V version AC100V -5 % to AC110V +10 %, 47 to 63 Hz, 1.0 kVA (*2)
*Extended-joint specification is not compatible with 100V input.

HM series
3-phase AC200V -15 % to AC240V +10 %, 47 to 63 Hz, 2.45 kVA
single phase AC230V -10 % to AC240V +10 %, 47 to 63 Hz, 2.45 kVA
HS series
3-phase AC200V -15 % to AC240V +10 %, 47 to 63 Hz, 1.8 kVA
single phase AC230V -10 % to AC240V +10 %, 47 to 63 Hz, 1.8 kVA
XR series
3-phase AC200V -15 % to AC240V +10 %, 47 to 63 Hz, 1.85 kVA
single phase AC230V -10 % to AC240V +10 %, 47 to 63 Hz, 1.85 kVA
I/O power supply Use external power supply Supply DC24V +/-10 % from outside
Use internal power supply Supply DC24V +/-10 % from inside controller
Safety performance (*3) Structure : Category 4

Performance Level : e

MTTFd : 100 years

DCavg : 99%

PFHd : 9.89×10-8

* Please specify the safety-I/O-less version in the case that safety I/O mounted on the standard version is not necessary

Stop category Category1 (except Safety-I/O-less type.)
(See IEC60204-1 for details of stop category)
Protect grade IP20
IP54 by using protective box (optional)
Stand for vertical setup Note) Set right side (power connector side) down
External dimension Standard : W 440.5 x D 299.6 x H 96.6 [mm] 12.8 L
UL : W 440.5 x D 400 x H 130 [mm] 17.8 L
Weight Standard : approximately 12 kg
UL : approximately 18 kg

*1: Expansion boards used in the RC7 robot controller cannot be used.

*2: If the power supply can be dropped 95V or less, such as in the heavily loaded facilities, using a transformer describes below is recommended. However, operation with 85V or lower voltage is not guaranteed.

Transformer specification

Input voltage : 1Ph 100V

Output voltage : 1Ph 200V

Capacity : 1kVA

*3 : This safety performance is determined for the robot stop functions; such as an emergency stop, enable auto, protective stop and deadman switch.
However, customer-prepared input devices (an emergency stop, enable auto, a switch connecting to the protective stop, etc.) are not included in the safety performance calculation

Calculation conditions

· This calculation is based on ISO 13849-1:2006.

· Expected operation time; 10 years (20 days / month)

· Start/ Stop (Motor ON/OFF) switching is expected 50 times a day.

· Expected operation time of the enable (deadman) switch ; 15200 times.

<< Prev        Next >>