VRC

Other parameters mentioned above.

Setting with the Teach Pendant

To set this parameter with a teach pendant, press [F6 Setting]-[F6 VRC Setting].
For details about operation, refer to "VRC Setting" of OPERATION GUIDE.

Parameter List

No. Item Name Unit Default Description
1 Record Err Level - 0 Set an error level for the error logging.
An error where the error level is equal to or higher than this selection will be recorded.
0: Level0 (Default)
1: Level1
2: Level2
3: Level3
4: Level4
5: Level5
4 Language mode - 0 Set the display language for pendant.
0: Japanese (Default)
1: English
2: German
3: Korean
4: Chinese
32 Slave mode command limit set - 0 This parameter is used to restrict available commands under the slave mode. Selecting "1: Enable" will restrict the commands.
0: Disable (Default)
1: Enable
36 Area check mode - 1 Select the way to check an area. Divide (old version) and CheckAll (the latest version) are available.
As from Ver.1.8.*, this item is set to "1: CheckAll" at the default to support high-speed processing.
The old version (Divide) is available by selecting "0: Divide".
0: Divide
1: CheckAll (Default)
37 Program priority mode set when starting. - 0 Set to enable or disable the Program priority mode at the controller startup.
* Enable this item when an error [81201001 Watchdog time over] occurs.
0: Disable (Default)
1: Enable