ID : 4504
Servo Log
More detailed recording of motor control.
The recording interval can be set from 1-8 ms.
The following data is logged.
- Motor speed command [r/min]
- Actual motor speed [r/min]
- Torque command [% of rating]
- Position deviation [deg]
- Motor angle target [deg or mm]
- Motor angle [deg or mm]
The recording range can be specified with the program.
The following commands are used.