<< Prev        Next >>

ID : 5835

Field Bus Parameter Setting

Set the robot controller with teach pendant.

From the top screen—[F4 I/O]—[F6 Aux.]-[F4 Field Bus parameter]

EtherNet/IP IP Address [IP Address]

Set an IP address. If it has already been set, currently set IP address is displayed.

EtherNet/IP Subnet mask [IP Address]

Set a subnet mask. If it has already been set, currently set subnet mask is displayed.

EtherNet/IP Gateway IP address [IP Address]

Set a subnet mask. If it has already been set, currently set subnet mask is displayed.

EtherNet/IP Bit Rate

Set the EtherNet/IP communication speed.

EtherNet/IP

Bit Rate

Set

automatically according to the connected device

100Mbps Full Duplex

100Mbps Half Duplex

10Mbps Full Duplex

10Mbps Half Duplex

Value 0 (Default Setting) 1 2 3

4

EtherNet/IP Insensitive time to network error [ms]

If the Communication check of EtherNet/IP communication starts too early after the Robot controller startup, an error [8350200B Prepare for field network communication] might be displayed immediately after booting.
To prevent such error, adjust "EtherNet/IP Insensitive time to network error" of Fieldbus parameter longer.

EtherNet/IP Insensitive time to network error [ms] Available range Default Setting
Value 0~65535

22000

EtherNet/IP DHCP Enable

If this parameter is enabled, an IP address used by EtherNet/IP is automatically obtained by DHCP.

EtherNet/IP DHCP Enable Enable Disable (Default Setting)
Value 1 0

EtherNet/IP ErrDisplay

This parameter allows you to choose whether the network error will display in "every time" or is display at the "first time" only.

This parameter is set to "0" (EveryTime) by default for safe operation of the facilities. Every time an I/O operation is carried out, an error will display if any.

To check program operations using dummy I/Os for setting up facilities where no connection to the network has been established, set this parameter to "1" (First Time). Doing so will not display errors once detected, allowing you to check program operations.

EtherNet/IP ErrDisplay First Time

EveryTime

(Default Setting)
Value 1

0

After completion of setting-up, be sure to set this parameter back to "0."

EtherNet/IP Input Run/Idle Header

Set this parameter when the top of the Input data from the EtherNet/IP Master shifts 32bits from the I/O port No. 512.

EtherNet/IP

Input Run/Idle Header

Enable Disable (Default Setting)
Value 1 0

EtherNet/IP Output Run/Idle Header

Set this parameter when the Output data of EtherNet/IP Master shifts by 32bit on the master side.

EtherNet/IP

Output Run/Idle Header

Enable Disable (Default Setting)
Value 1 0

ID : 5835

<< Prev        Next >>