Quarterly Inspections
Check Items
Check the items listed below every three months.
| No. | Check: | Controller Power | How to check: | Criterion | What to do: |
|---|---|---|---|---|---|
| 1 | Robot base mounting bolts | OFF | Measure the tightening torque with a torque wrench. | No looseness. Specified torque: 70± 14 Nm | Tighten the bolts to the specified torque. |
| 2 | Cooling fan filters in the robot controller | OFF | Visually | No dust or dirt. | Clean the cooling fan filters. |
Cleaning the Cooling Fan Filters in the Robot Controller
For the cleaning procedures of the air intake filter, refer to the RC8 CONTROLLER MANUAL, "Cleaning Intake Port Filter ".