Quarterly Inspections

Check Items

Check the items listed in the table below every three months.

Quarterly Inspections Table

No. Check: Controller Power How to check: Criterion What to do:
1 Robot base mounting bolts OFF Measure the tightening torque with a torque wrench.

No looseness.

Specified torque:

128 ±26 Nm

Tighten the bolts to the specified torque.
2 Cooling fan filters in the robot controller OFF Visually No dust or dirt. Clean the cooling fan filters.

Cleaning the Cooling Fan Filters in the Robot Controller

For the cleaning procedures of the air intake filter, refer to the RC8 CONTROLLER MANUAL, "Cleaning Intake Port Filter ".