Signal Wiring and Air Piping
Signal wirings and air piping shall be prepared by customers.
The cableveyor stores cables and pipes up to 50% of the cross sectional area of its wiring and piping space.
The following shows the size of available wiring and piping space and the number of cables/pipes that can be stored.
| Robot type | Empty space of cableveyor | Allowed number of cables/pipes | ||
|---|---|---|---|---|
| mm² | φ10 | φ8 | φ6 | |
| LZNN, LSNN | 669 | 6 | 10 | 18 |
LYZN, LZZN LSSN, LZSN |
569 | 5 | 8 | 15 |
| LYZZ, LZSS | 469 | 4 | 7 | 13 |
- Wiring and piping example for the S axis
The below PDF data shows the recommended wiring and piping examples for a system which connects an end effecter (such as a hand) to the end of the motion range of the S-axis.
LSNN, LSSN wiring and piping example (PDF:123KB)
LZSN, LZSS wiring and piping example (PDF:136KB)
- Related Information
- Existing Internal Threads for Wiring and Piping