ID : 7644
MC_WriteDOByte
To write an I/O output signal of robot controller. (Byte)
| Graphic expression | FB category |
|---|---|
![]() |
Non motion |
Input and Output Variable
| Variable name | Data type | Valid range | Default | Omission (*) |
|---|---|---|---|---|
| AxesGroup | eRC_AxesGroup | No | ||
|
||||
Input Variable
| Variable name | Data type | Valid range | Default | Omission (*) |
|---|---|---|---|---|
| Execute | Boolean |
|
FALSE | No |
|
||||
| IoType | Integer | 0, 1 | 0 | Yes |
|
||||
| IoByteNo | Integer |
|
0 | Yes |
|
||||
| Value | Byte | 0 to 255 | 0 | Yes |
|
||||
(*) : For some Variable, entries can be omitted.
- Yes : Entry can be omitted.
- No : Entry required always.
Output Variable
| Variable name | Data type / Description |
|---|---|
| Done | Boolean |
|
|
| Busy | Boolean |
|
|
| Error | Boolean |
|
|
| ErrorID | Word |
|
|
| ErrorIDEx | DWord |
|
Function Description
This function block writes an I/O output signal of robot controller.
Robot controller's port number corresponding to the byte number will be turned ON/OFF. For example, to turn ON the port number 20 of the robot controller, specify IoType : 1, IoByteNo : 0, and Value : 32.
The following tables show the correspondence between robot controller port number and byte number.
- Hand I/O
IoByteNo Robot controller port number Robot controller I/O name 0 64 Hand output 65 Hand output 66 Hand output 67 Hand output 68 Hand output 69 Hand output 70 Hand output 71 Hand output - Mini I/O
IoByteNo Robot controller port number Robot controller I/O name 0 16 CPU Normal 17 User output 18 User output 19 User output 20 User output 21 User output 22 User output 23 User output 1 24 User output 25 User output 26 User output 27 User output 28 User output 29 User output 30 User output 31 User output
Attention
This function block is available only when the I/O allocation of Mini I/O is "All user I/O".
ID : 7644