ID : 10169
Specification of Robot Controller
This page describes the specifications divided into the following items.
- Robot Controller Name, Model Code, Applicable Robot
- Outer Dimensions, Weight
- Environmental Conditions for Installation Site
- Power Source
- Structure
- Robot Control
- Programming
- I/O
- Communication
- Operation Devices
- Safety
Robot Controller Name, Model Code, Applicable Robot
| Robot controller name | RC9M |
|---|---|
| Model code |
|
| Applicable robot |
|
Outer Dimensions, Weight
| Outer dimensions |
W600 × D581 × H600 [mm] For details, see the drawing. |
|---|---|
| Weight | Approx. 93 kg |
Environmental Conditions for Installation Site
| Installation orientation | Stand-alone |
|---|---|
| Ambient temperature | During operation: 0 to 40°C During storage and transport: -10 to 60°C |
| Relative humidity | During operation: 20 to 90% RH (No dew condensation allowed.) During storage and transport: 40 to 75% RH (No dew condensation allowed.) |
| Altitude | During operation: 1,000 m or less |
| Safe installation environment | Refer to "Insuring the Proper Installation Environment" in Safety Precautions. |
| Working space | Sufficient space must be available for inspection and disassembly. |
| Grounding conditions |
Grounding resistance (protective ground): 100Ω or less. If the power transformer box is used, the grounding resistance (protective ground) must be 10Ω or less. |
Power Source
| Power source specifications |
3-phase 200 VAC -10% to 230 VAC +10%, 47 to 63 Hz, 4.5 kVA (If the power transformer box is used: 3-phase 400 VAC -10% to 480 VAC +10%, 47 to 63 Hz, 4.5 kVA) |
|---|---|
| Cable | Use the AC power cable (10 m), which is a required option that you need to select when purchasing the controller. Ensure the bending radius (internal) of the AC power cable is 114 mm or more. The cable may be broken if bent excessively. |
Structure
| Installation orientation | Floor-mounted (fixed with bolts) |
|---|---|
| Degree of protection | IP54 |
| Defacement (pollution) degree | 3 |
Robot Control
| Number of axes controlled | 6 axes |
|---|---|
| Control method | PTP, CP 3-dimensional linear, 3-dimensional arc |
| Cable |
|
Programming
| Language | DENSO Robotics language PacScript |
|---|---|
| Memory capacity |
|
| Teaching method |
|
| Timer accuracy | 1 msec |
I/O
| Safety I/O |
Number of Pins
Overview
|
|---|---|
| Digital I/O |
Number of Pins
Overview
|
| Hand I/O |
Number of Pins
Overview
|
| User Power |
Overview
Power Source Specifications
|
| Options |
The following devices are also available as options. Field Network Slave
Only one field network slave terminal can be used for one robot controller. Digital Input
Digital Output
Digital Input/Output
|
Communication
| Ethernet | Side of the robot controller: 1 line (GbE: Gigabit Ethernet) |
|---|---|
| USB |
|
| Options |
The following devices are also available as options. Serial Communication
You cannot use multiple same terminals for one robot controller. Ethernet
|
Operation Devices
Smart TP |
|
|---|---|
| Mini-pendant |
|
| Pendant extension cable |
|
Safety
| Safety performance (*1) |
|
|
|---|---|---|
| Self-diagnosis function | It detects an overrun, servo error, memory error, input error, short circuit (in user wiring), and other errors. | |
| Error indication |
|
|
| SCCR | 5 kA | |
| Safety-related control system | Type |
|
| Performance |
|
|
| Over-voltage category | III | |
| Electric shock protection class | I | |
To check the safety functions, restart the robot controller once every 24 hours.
*1: The safety performance described here is the safety performance of the robot stop functions (Emergency Stop, Enable Auto, Protective Stop, and the enabling switch). The performance calculation does not include input devices that you need to prepare yourself (such as switches connected to Emergency Stop, Enable Auto, and Protective Stop).
Calculation Conditions
- The calculation is based on ISO 13849-1:2015.
- The annual number of operations (Nop) is estimated as follows.
| Operation | Mission time (year) | |
|---|---|---|
| 10 | 20 | |
| Start/Stop (Motor ON/OFF) | 20,683 | 19,466 |
ID : 10169
- Related Information
- Controller Type