ID : 10599
Assembling Procedure to 2nd Axis

1
Remove the protective components from the vicinity of notch (A)(B).

2
By using the smart TP, move the robot axis to the CALSET position and make the notch (C) and the notch (D) closer.

3
Assemble the dial gauge holder to the hole beside the notch (D).
4
Insert the dial gauge (E) to the holder.
Push the dial gauge in for about 2.5 mm.

This completes assembling.