<< Prev        Next >>

ID : 10880

Quick Reference Table for the Number of Input/Output Slots

The following table shows the number of input/output slots and the maximum number of user I/O ports. Robot controllers allow adding or removing I/O ports by one byte, this will determine the number of I/O port that the robot controller can handle.

  Available range (byte) Defalt setting (byte)
The number of input slots 5~32

8

The number of output slots 4~32 7

Number of User Input Points

The number of input slots

(byte)

The maximum number of user Input points

5 0
6 8
7 16
8 24
9 32
10 40
11 48
12 56
13 64
14 72
15 80
16 88
17 96
18 104
19 112
20 120
21 128
22 136
23 144
24 152
25 160
26 168
27 176
28 184
29 192
30 200
31 208
32 216

Number of User Output Points

The number of output slots

(byte)

The maximum number of user output points

4 0
5 8
6 16
7 24
8 32
9 40
10 48
11 56
12 64
13 72
14 80
15 88
16 96
17 104
18 112
19 120
20 128
21 136
22 144
23 152
24 160
25 168
26 176
27 184
28 192
29 200
30 208
31 216
32 224