ID : 11047
Requirements for a User-Prepared IPC
While the IPC-equipped MC9 controller cannot control motors with an IPC you prepare, the IPC-less MC9 controller can control motors with a BECKHOFF IPC that you prepare.
An IPC to be used for controlling the IPC-less MC9 controller must satisfy the specifications in the following table.
| Operating environment requirements | |
|---|---|
| IPC | IPC manufactured by BECKHOFF |
| OS | Windows 10 IoT Enterprise LTSC |
| TwinCAT version |
|
| CPU | Intel(R) 1.91GHz, 4 Cores or more (*2) |
| Memory size | 4 GB or more |
| Storage space | 40 GB or more available storage space |
| Number of Ethernet ports | 4 ports or more (*3) (*4) |
| Number of USB ports | 2 ports or more |
*1: Use the latest version (3.1.4024) of TwinCAT.
*2: TwinCAT and VRC require two cores respectively.
*3: The network adopter name must be changeable.
*4: The two ports to be used for TwinCAT must be compatible with EtherCAT communication.
The other two ports not to be used for TwinCAT can also be used with a USB to LAN adapter.
ID : 11047