ID : 28
Pin Assignment on Signal Line Connectors (CN20, CN21)

Pin Assignment on CN20 and CN21

Wiring between CN20 and CN21, and Wiring from Solenoid Valves
Pins on CN20 | Pins and solenoid valve input on CN21 (allowable current/allowable voltage) | |
---|---|---|
Standard flange | Communication interface flange-A | |
A | CN21 -1 (1.0 A / 50 VAC) | CN21 -1 (1.0 A / 50 VAC) |
B | CN21 -2 (1.0 A / 50 VAC) | CN21 -2 (1.0 A / 50 VAC) |
C | CN21 -3 (1.0 A / 50 VAC) | CN21 -3 (0.5 A / 50 VAC) |
D | CN21 -4 (1.0 A / 50 VAC) | CN21 -4 (0.5 A / 50 VAC) |
E | CN21 -5 (1.0 A / 50 VAC) | (No connection) |
F | CN21 -6 (1.0 A / 50 VAC) | (No connection) |
G | CN21 -7 (0.5 A / 50 VAC) | (No connection) |
H | CN21 -8 (0.5 A / 50 VAC) | (No connection) |
J | CN21 -9 (0.5 A / 50 VAC) | (No connection) |
K | CN21 -10 (0.5 A / 50 VAC) | (No connection) |
L | - | - |
M | "Solenoid valve, +24V (NPN) / 0V (PNP)" | "Solenoid valve, +24V (NPN) / 0V (PNP)" |
N | Solenoid valve 1A (Solenoid valve 1) | Solenoid valve 1A (Solenoid valve 1) |
P | Solenoid valve 1B (Solenoid valve 1) | Solenoid valve 1B (Solenoid valve 1) |
R | Solenoid valve 2A (Solenoid valve 2) | Solenoid valve 2A (Solenoid valve 2) |
S | Solenoid valve 2B (Solenoid valve 2) | Solenoid valve 2B (Solenoid valve 2) |
T | Solenoid valve 3A (Solenoid valve 3) * | Solenoid valve 3A (Solenoid valve 3) * |
U | Solenoid valve 3B (Solenoid valve 3) * | Solenoid valve 3B (Solenoid valve 3) * |
V | - | - |
* Not used on the VS-050/060.
ID : 28