[PNP type] Emergency Stop Circuit for RC8

For Safety-I/O-less Version

The following figure shows the example of configuration and connection of emergency stop circuit on the standard type of the controller. In the RC7M controller, the emergency stop circuit consists of dual safety circuits.

The emergency stop button on the teach pendant can be used also as an emergency stop switch of the equipment.

Pendant Emergency Stop output signals

Pendant Emergency Stop output signal (Dry output)

The two contacts on the emergency stop button (4b) on the teach pendant are connected. This signal will be issued independent of the ON/OFF state of the controller power.

Emergency Stop Circuit in the RC8 Controller

Please refer to this if the figure is not clear. (PDF:162KB)