ID : 4656
Quarterly Inspections
Check Items and Lubrication
Check the items listed below every three months.
Quarterly Inspections Table
No. | Check: | Controller Power | How to check: | Criterion | What to do: |
---|---|---|---|---|---|
1 | Robot base mounting bolts | OFF | Measure the tightening torque with a torque wrench. | No looseness. Specified torque: 128 ±20 Nm |
Tighten the bolts to the specified torque. |
2 | Cooling fan filters in the robot controller | OFF | Visually | No dust or dirt. | Clean the cooling fan filters. |
Cleaning the Cooling Fan Filtersin the Robot Controller
For the cleaning procedures of the air intake filter, refer to the RC8 SERIES ROBOT CONTROLLER MANUAL, "Cleaning Intake Port Filter".