ID : 4747
HS/HSS-W, HS-P (Dust- & Splash-proof Type or Cleanroom Type)
Please refer to this if the figure is not clear.(PDF:588KB) |
||
Notes for cleanroom type *1 Recommended suction air flow rate: 25 to 40 liters/min. Recommended blower: VFC068P (manufactured by Fuji Electric Motor Co., Ltd.) The cleanroom type requires ventilation inside the robot. Exhaust air from the air vent provided in the back of the robot base. *2 Dimension D at point of use HS-4535*-P: 250 mm HS-4545*-P: 350 mm HS-4555*-P: 400 mm |
||
Air No. | Air piping joint | Maximum allowable pressure |
---|---|---|
AIR 1, 2 | φ4, PT1/8 | 0.59 MPa |
AIR 3, 4 | φ6, PT1/4 |
Note 1: Pins A to V on CN20 and pins #1 to #19 on CN21 are connected with each other as shown below. The maximum rated current per line is 1A.
CN20 | A | B | C | D | E | F | G | H | J | K |
---|---|---|---|---|---|---|---|---|---|---|
CN21 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
CN20 | L | M | N | P | R | S | T | U | V | - |
CN21 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | - |
Note 2: Use the attached connector set for CN20 and CN21.
Connector set part No. | Part No. | Model and Name | Appearance | |
---|---|---|---|---|
410889-008* | 410877-012* |
H/M3106A22-14S |
||
410877-013* |
H/MS3057-12A |
Applicable wire diameter φ11.4 to 15.9 |
||
410877-014* |
H/MS3057-12A1 |
Applicable wire diameter φ8 to 11.6 |
||
410877-044*(*1) |
WEBSP2119M-1-D(R1) |
Applicable wire diameter φ10.5 to 14.1 |
*1: The connector design was changed in May 2019. As these connectors are interchangeable, either connector can be used for robot connection. However, applicable wire diameter is different from the old and new models. If you use a new connector, select a cable that satisfies the applicable wire diameter listed in the above table.
ID : 4747