ID : 5547
Specifications
Environmental Requirements
| Item | Specifications |
|---|---|
| Operating temperature | 0 to 40℃ |
| Operating humidity | 90% RH or less (without condensation) |
DeviceNet Communications Specifications
| Item | Specifications | |||
|---|---|---|---|---|
| Communications protocol | DeviceNet-compliant | |||
| Connection supported | Master/slave connection : Polling I/O function, Compliant with DeviceNet communications rules | |||
| Connection type *1 | Multi-drop type with possible combination of T-branch (to trunk and branch lines) | |||
| Bit rate | 500, 250, 125 kbps | |||
| Communications media | Dedicated cable consisting of 5 wires (2 for signals, 2 for power supply and 1 as a shield wire) | |||
| Communications cable length | Bit rate | Max. network length *2 | Branch length | Total branch length |
| 500 kbps | 100 m or less | 6 m or less | 39 m or less | |
| 250 kbps | 250 m or less | 6 m or less | 78 m or less | |
| 125 kbps | 500 m or less | 6 m or less | 156 m or less | |
| Power supply for communication | External supply of 24 VDC ±10% | |||
| Internal power consumption | Communication power source: 65 mA maximum. | |||
| Maximum number of connectable nodes | 64 nodes (including configurator (converter) if connected) | |||
| Error check | CRC | |||
|
*1 Terminator resistors are needed at both ends of the trunk line. (121 Ω) *2 These values may apply when a special thick cable is used as a trunk line. If a special fine cable is used, the maximum network length is 100 m or less. |
||||
DeviceNet Master Board Specifications
| Item | Specifications |
|---|---|
| Number of user inputs | 0 to 1024 points |
| Number of user outputs | 0 to 1024 points |
| Limitation of I/O point per node | No limit |
| Unit of I/O allocation | The number of I/Os can be set in unit of 8 points. |