VM-6083(Nickname: VM1000)
VM-6083 Specifications
|
Item |
Specifications |
||
|---|---|---|---|
| Standard type (VM) | Dust- & splash-proof type (VM-W) | ||
|
Model name of robot set (* 1) |
VM-6083 | VM-6083-W | |
|
Model name of robot unit |
VM-6083D/M | VM-6083D/M-W | |
|
Overall arm length |
385 (first arm) + 445 (second arm) = 830 mm |
||
|
Arm offset |
J1 (swing): 180 mm J3 (front arm): 100 mm |
||
|
Maximum workable space |
R = 1,111 mm (end-effector mounting face) R = 1,021 mm (Point P: J4, J5, J6 center) |
||
|
Motion range |
J1: ±170° J2: +135°, -90° J3: +165°, -80° J4: ±185° J5: ±120° J6: ±360° |
||
|
Maximum payload |
13Kg (*4) |
||
|
Maximum composite speed |
8,300 mm/s (at the center of an end-effector mounting face) |
||
|
Position repeatability (* 2) |
In each of X, Y and Z directions: ±0.05 mm (at the center of an end-effector mounting face) |
||
|
Maximum allowable inertia moment |
Around J4 and J5: 0.36 kgm2 Around J6: 0.064 kgm2 |
||
|
Position detection |
Absolute encoder |
||
|
Drive motor and brake |
AC servomotors for all joints, Brakes for joints J2 to J6 |
||
|
User air piping (* 3) |
7 systems (φ4x6, φ6x1), 3 solenoid valves (2-position, double solenoid) contained. |
||
|
User signal line |
10 (for proximity sensor signals, etc.) |
||
|
Air source |
Operating pressure |
0.10~0.39MPa |
|
| Maximum allowable pressure |
0.49MPa |
||
|
Airborne noise (A-weighted equivalent continuous sound pressure level) |
80 dB or less |
||
|
Degree of protection |
IP40 | IP54 (Wrist: IP65) | |
|
Weight |
Approx. 82 kg (180 lbs) | Approx. 86 kg (189 lbs) | |
*1: The model name of robot set refers to the model name of a complete set including a robot unit and robot controller.
*2: Position repeatability is the value at constant ambient temperature.
*3: Only the φ4x6 air piping system may be controlled by built-in solenoid valves.
*4: When operating with 11kg or more payload, turn the flange to a downward direction then keep the end-effector flange face position within +/-10 degree from the vertical.