ID : 10356

Continue Start Permission (output): Selectable by I/O Parameters

Terminal #28 on Digital I/O connector (port 24) is assigned a user output by factory default. It can be assigned the Continue Start Permission output signal with the I/O Parameters.

To assign the continue start permission output, using the smart TP, go to [F4 I/O] - [F6 Aux] - [F5 I/O Parameters] then change the value of [User or System output setting] to 1.

Details when setting the "Continue Start Permission" are as shown below.

Function

The controller will output this signal when Continue Start is permitted.

Terminal number

#28 on Digital I/O connector

Usage

Use this signal when you want to know whether Continue Start is permitted.

ON condition

This signal comes on when Continue Start is permitted. For details, refer to the SETTING-UP MANUAL, "Continue Function."

OFF condition

This signal goes off by operations that change the task status (example: Program reset).

ID : 10356