ID : 10348
[Mini I/O Dedicated Allocation] Types and Functions of System Output Signals
The table below lists the system output signals.
| Application | Output signal name | Function |
|---|---|---|
|
Start-up |
Robot Initialized | Outputs to the external device that the OPERATION PREPARATION command is executable. |
| Auto Mode | Outputs when the robot is in Auto mode. | |
| Operation Preparation Completed | Outputs when the motor power is turned on and the robot is in External auto mode. | |
| Program execution | Robot Running | Outputs when the robot is in operation (one or more tasks are being executed). |
|
Error/Warning |
CPU Normal | Outputs when the CPU of the robot controller is normal. |
| Robot Error | Outputs when a servo error, program error, or any other serious error occurs. | |
| Battery Warning | Outputs when the voltage of the encoder or memory backup battery drops below the specified level. | |
| Continue |
Note : It is necessary to specify this output signal by I/O parameters beforehand. |
Outputs when Continue Start is permitted. |
System output signals are checked every 8 ms.
ID : 10348