Project Property Setting

To use a PROFIBUS slave board as an I/O expansion board, you need to register the following information from WINCAPSIII.

From the [Project] menu, point to [Property] to open the Property window, and then click .[I/O] tab. For details, refer to "Configuring a Project".

 

Assign

Device

  Setting value
Device "PROFIBUS Slave" or "[Parallel] + [PROFIBUS Slave]"

Mode

"Standard" indicates the Standard mode, and "Compatible" indicates the RC3 Compatible mode. For details about allocation modes, refer to “Functions in Individual Allocation Modes ”.

  Setting value
Mode "Compatible" or "Standard"

Options MiniIO

Power source

If the total maximum capacity of Mini I/O, Hand I/O and Parallel I/O is 1.3 A or lower, the internal power source is available.

  Setting value Defalt setting
Power source "External" or "Internal" External

Options PROFIBUS

Input / Output Setting

For about the number of IO points, refer to “Quick Reference Table for the Number of Input/Output Slots".  I/O can be added or removed by one byte; this will determine the maximum number of I/O.

  Setting value (byte) Default Setting (byte)
Input setting "8", "12", "16", "20" or "32"

8

Output setting "8", "12", "16", "20" or "32" 8

Node Address

  Available range Default Setting
Node address 1 to 125 1

 

ID : 1061