ID : 1061
Project Property Setting
To use a PROFIBUS slave board as an I/O expansion board, you need to register the following information from WINCAPSIII.
From the [Project] menu, point to [Property] to open the Property window, and then click .[I/O] tab. For details, refer to "Configuring a Project".

Assign
Device
| Setting value | |
|---|---|
| Device | "PROFIBUS Slave" or "[Parallel] + [PROFIBUS Slave]" |
Mode
"Standard" indicates the Standard mode, and "Compatible" indicates the RC3 Compatible mode. For details about allocation modes, refer to “Functions in Individual Allocation Modes ”.
| Setting value | |
|---|---|
| Mode | "Compatible" or "Standard" |
Options MiniIO
Power source
If the total maximum capacity of Mini I/O, Hand I/O and Parallel I/O is 1.3 A or lower, the internal power source is available.
| Setting value | Defalt setting | |
|---|---|---|
| Power source | "External" or "Internal" | External |
Options PROFIBUS
Input / Output Setting
For about the number of IO points, refer to “Quick Reference Table for the Number of Input/Output Slots". I/O can be added or removed by one byte; this will determine the maximum number of I/O.
| Setting value (byte) | Default Setting (byte) | |
|---|---|---|
| Input setting | "8", "12", "16", "20" or "32" | 8 |
| Output setting | "8", "12", "16", "20" or "32" | 8 |
Node Address
| Available range | Default Setting | |
|---|---|---|
| Node address | 1 to 125 | 1 |
ID : 1061
- Related Information
- Quick Reference Table for the Number of Input/Output Bytes
- I/O Allocation