Project Property Setting

To use a CC-Link remote device board as an I/O expansion board, you need to register the following information from WINCAPSIII.

From the [Project] menu, point to [Property] to open the Property window, and then click .[I/O] tab. For details, refer to "Configuring a Project".

 

Assign

Device

  Setting value
Device

"CC-Link RD" or "[Parallel] + [CC-Link RD]"

Mode

"Standard" indicates the Standard mode, and "Compatible" indicates the RC3 Compatible mode. For details about allocation modes, refer to “Functions in Individual Allocation Modes ”.

  Setting value
Mode "Standard"or "Compatible"

Options MiniIO

Power source

If the total maximum capacity of Mini I/O, Hand I/O and Parallel I/O is 1.3 A or lower, the internal power source is available.

  Setting value Defalt setting
Power source "External" or "Internal" External

 

Options CC-Link

Only "Occupied stations" and "Extended cyclic setting (for Ver.2.00)" can change the number of User I/O.

Set desired I/O numbers with referring to "I/O Allocation".

Version

  Setting value Defalt setting
Version "1.1" or "2.0" 1.1

Station number

  Setting range Defalt setting
Station number 1~63 1

Occupied stations

  Setting range Defalt setting
Occupied stations 2~4 4

Extention Cycles

Extension Cycle setting is available from Version 2.00 or later. You do not need to set this if your CC-link version is 1.1.

  Setting range Defalt setting

Extention Cycles

"1", "2", "4" or "8" 1

Baud Rate

  Setting value Defalt setting
Baud Rate "156K", "625K", "2.5M", "5M" or "10M" 10M

 