ID : 2261
Setting Up Exclusive Communication and Exclusive Monitoring
Set each controller as a master or slave.
Exclusive Communication
Operation path : Basic screen - [F2 Arm] - [F6 Aux] - [F11 Exclusive Control]
Press [F2 Exclusive Comunication] to open the screen.
Settings Required for both the Master and Slave Controllers
Selecting [Exclusive control controller configuration] and pressing [F5 Edit] will enable you to select a master or slave controller.
Enter 1 to set the controller as Master, or enter 2 to set the controller as Slave, and then press [OK].
No. | Item Name | Unit | Default | Description |
---|---|---|---|---|
329 | Exclusive control controller configuration | - | 0 |
Set a robot controller as a master or slave controller. 0 : No setting 1: Master controller 2: Slave controller |
Settings Required only for the Master Controller
For a master controller, perform communication settings as well.
Operation path : Basic screen - [F2 Arm] - [F6 Aux] - [F11 Exclusive Control] - [F2 Exclusive Comunication]
Press the [F5 Edit] button to open the numeric keypad. Enter the IP address of a target controller for the exclusive control function, and press [OK].
When you enter the IP address of "0.0.0.0", the controller can be excluded from the exclusive group.
Parameter List
No. | Item Name | Unit | Default | Description |
---|---|---|---|---|
330 | Exclusive control IP(0)[IP Address] | - | 127.0.0.1 | Enter the IP address of exclusive control's master controller. |
331 | Exclusive control IP(1)[IP Address] | - | 0.0.0.0 | Enter an IP address of slave controller. |
332 | Exclusive control IP(2)[IP Address] | - | 0.0.0.0 | Enter an IP address of slave controller. |
333 | Exclusive control IP(3)[IP Address] | - | 0.0.0.0 | Enter an IP address of slave controller. |
362 | Exclusive control slave connection timeout[sec] | sec | 30 |
Set the latency time of slave controller's start-up. Master controller will wait the startup of slave controllers by this period. |
367 | Exclusive control waiting timeout [sec] | sec | 300 | Specify the upper limit of the time for the robot to wait during exclusive control. If the waiting time exceeds the specified value, the error [0x83201567: Exclusive control wait timeout.] occurs. |
Exclusive Monitoring
Perform this setting for the master and/or slave controllers as needed.
When you perform this setting, set the user level to "Maintainer".
Operation path : Basic screen - [F2 Arm] - [F6 Aux] - [F11 Exclusive Control] - [F3 Exclusive Monitoring]
Press [F3 Exclusive Monitoring] to open the window.
Press [F5 Edit] to open the ten-key, enter the monitoring cycle and then press [OK].
No. | Item Name | Unit | Default | Description |
---|---|---|---|---|
363 | Exclusive control monitoring cycle | ms | 8 | Set the monitoring cycles. |
If the monitoring cycle causes timeout, firstly reduce the number of monitoring models. If there is no effect for that, set the parameter [363: Exclusive control monitoring cycle] longer than 8 ms.
ID : 2261