Setting Up Exclusive Communication and Exclusive Monitoring

Set each controller as a master or slave.

Exclusive Communication

Operation path : Basic screen - [F2 Arm] - [F6 Aux] - [F11 Exclusive Control]

Press [F2 Exclusive Comunication] to open the screen.

Settings Required for both the Master and Slave Controllers

Selecting [Exclusive control controller configuration] and pressing [F5 Edit] will enable you to select a master or slave controller.

Enter 1 to set the controller as Master, or enter 2 to set the controller as Slave, and then press [OK].

No. Item Name Unit Default Description
329 Exclusive control controller configuration -

0

Set a robot controller as a master or slave controller.
0 : No setting
1: Master controller
2: Slave controller

Settings Required only for the Master Controller

For a master controller, perform communication settings as well.

Operation path : Basic screen - [F2 Arm] - [F6 Aux] - [F11 Exclusive Control] - [F2 Exclusive Comunication]

Press the [F5 Edit] button to open the numeric keypad. Enter the IP address of a target controller for the exclusive control function, and press [OK].

When you enter the IP address of "0.0.0.0", the controller can be excluded from the exclusive group.

Parameter List

No. Item Name Unit Default Description
330 Exclusive control IP(0)[IP Address] - 127.0.0.1

Enter the IP address of exclusive control's master controller.
To include the master controller into the exclusive group, use the default value. To exclude it from the exclusive group, enter "0.0.0.0".

331 Exclusive control IP(1)[IP Address] - 0.0.0.0 Enter an IP address of slave controller.
332 Exclusive control IP(2)[IP Address] - 0.0.0.0 Enter an IP address of slave controller.
333 Exclusive control IP(3)[IP Address] - 0.0.0.0 Enter an IP address of slave controller.
362 Exclusive control slave connection timeout[sec] sec

30

Set the latency time of slave controller's start-up. Master controller will wait the startup of slave controllers by this period.
367 Exclusive control waiting timeout [sec] sec 300 Specify the upper limit of the time for the robot to wait during exclusive control. If the waiting time exceeds the specified value, the error [0x83201567: Exclusive control wait timeout.] occurs.

Exclusive Monitoring

Perform this setting for the master and/or slave controllers as needed.

When you perform this setting, set the user level to "Maintainer".

Operation path : Basic screen - [F2 Arm] - [F6 Aux] - [F11 Exclusive Control] - [F3 Exclusive Monitoring]

Press [F3 Exclusive Monitoring] to open the window.

Press [F5 Edit] to open the ten-key, enter the monitoring cycle and then press [OK].

No. Item Name Unit Default Description
363 Exclusive control monitoring cycle ms 8 Set the monitoring cycles.

If the monitoring cycle causes timeout, firstly reduce the number of monitoring models. If there is no effect for that, set the parameter [363: Exclusive control monitoring cycle] longer than 8 ms.

 