ID : 2353

Specification of RC8A Controller

Term Specification
Applicable robot VM-6083 / VM-60B1

VS-6556 / VS-6577

VS050 / VS060 / VS068 / VS087

VP-6242 / VP-5243

HM series / HS series / HSA1 series / HSR series

XR series / SC series

Type RC8A-****-****-**-***
Number of axes controlled Robot : 4 to 6 axes
Extended-joint : 2 to 4 axes (optional)
Control method PTP, CP 3-dimensional linear, 3-dimensional arc
(For SC series and Extended-joints, available PTP control only.)
Drive method All axes all digital AC servo
Language in use DENSO Robotics language (PacScript)
Memory capacity User area, Variable area : 1.75 Mbyte (32,766 points equivalent), File area : 400 Mbyte (5,000 steps x 256 files)
Teaching method
  1. Direct teaching...Horizontal articulated model only
  2. Remote teaching
  3. Numerical entry (MDI)
External signal
(I/O, etc.)
Mini I/O

Input : User open 8 points + System fix 14 points
Output : User open 8 points + System fix 18 points

Hand I/O

Input : 8 points

Output : 8 points

Safety I/O Input and output signals are integrated into Mini I/O connector.
Motion I/O
(optional)

Input : Safety circuit signal 30 points

Output : Safety circuit signal 14 points

Parallel I/O board
(optional) (*1)
Expansion slot : PCI

Input : 40 points

Output : 48 points

CC-Link remote device board
(optional) (*1)
Expansion slot : PCI Express

Input : Up to 8192 points

Output : Up to 8192 points

Remote register

Input : Up to 2048 words

Output : Up to 2048 words

DeviceNet slave board
(optional) (*1)
Expansion slot : PCI Express

Input : Up to 256 points

Output : Up to 256 points

DeviceNet master board
(optional) (*1)
Expansion slot : PCI Express

Input : 1024 points

Output : 1024 points

EtherNet/IP Adapter board
(optional) (*1)
Expansion slot : PCI Express

Input : Up to 4032 points

Output : Up to 4032 points

PROFIBUS slave board
(optional) (*1)
Expansion slot : PCI Express

Input : Up to 256 points

Output : Up to 256 points

PROFINET IO Device board
(optional)
Expansion slot : PCI Express

Input : Up to 8192 points

Output : Up to 8192 points

EtherCAT slave board
(optional)
Expansion slot : PCI Express

Input : Up to 2048 points

Output : Up to 2048 points

RS232C expansion board
(optional, not supplied)
DENSO supplies software only and board is not supplied.
External communication RS232C 1 line
Ethernet 1 line (GbE: Gigabit Ethernet)
USB 2 lines
VGA optional 1 line
Electric gripper control board
(optional) (*1)
Expansion slot : PCI
Expansion slot
  • PCI 1 slot
  • PCI Express 1 slot
Self diagnosis function Overrun, servo error, memory error, input error, short circuit detection (user wiring part), etc.
Timer function 0.02 to 10 sec. (1/60 sec. step)
Error display
  • External error output
  • Display error code on mini-pendant (optional)
  • Display error message, resume method on teach pendant (optional)
Cable Motor & encoder cable for RC8 series
(optional)
2 m, 4 m, 6 m, 12 m, 20 m

Note) Motor connector x 3, encoder connector x 1
Note) VM, HS, HM are standard / splash-proof version
Note) VS is dedicated version
Note) SC is only for 4m, 6m and 12m Motor cable (connector x 1), encoder cable (connector x 1)
Note) The 20m cable is not available for the UL-listed robot unit.

I/O cable
(optional)
8 m, 15 m
(for Mini I/O, for Hand I/O, for expansion parallel I/O)

For Motion I/O cable
(optional)

8 m, 15 m
RC8 series power cable 5 m
For RC8 series Extended-joint
motor cable (optional)
2 m, 4 m, 6 m, 12 m
(standard version)
For RC8 series Extended-joint
encoder cable (optional)
1 m, 2 m, 4 m, 6 m, 12 m
(standard version)
External operation
device
Teach pendant
(optional)
4 m, 8 m, 12 m
Mini-pendant
(optional)
4 m, 8 m, 12 m
Emergency stop switch box
(optional)
4 m
Pendant extension cable
(optional)
4 m, 8 m
(Available for Emergency stop switch box as well)
Environmental condition (in motion) Temperature 0 to 40 degree C, humidity 20 to 90% RH (No dew condensation allowed.)
Defacement (pollution) degree 2 (*2)
Power supply(*3) VM
3-phase 200 VAC -15% to 240 VAC +10% 47 to 63 Hz, +3.3 kVA
VS-6556/6577
3-phase 200 VAC -15% to 240 VAC +10% 47 to 63 Hz, 1.8 kVA
Single phase 230 VAC -10% to 240 VAC +10% 47 to 63 Hz, 1.8 kVA
VS-050/060
3-phase 200 VAC -15% to 240 VAC +10% 47 to 63 Hz, 1.15 kVA
Single phase 230 VAC -10% to 240 VAC +10% 47 to 63 Hz, 1.15 kVA
VS-068/087
3-phase 200 VAC -15% to 240 VAC +10% 47 to 63 Hz, 2.78 kVA
Single phase 230 VAC -10% to 240 VAC +10% 47 to 63 Hz, 2.78 kVA
VP
3-phase 200 VAC -15% to 240 VAC +10% 47 to 63 Hz, 1.0 kVA
Single phase 230 VAC -10% to 240 VAC +10% 47 to 63 Hz, 1.0 kVA

100V version AC100 V -5 % to AC110 V +10% 47 to 63 Hz, 1.0 kVA (*4)
* Extended-joint specification does not support 100 V input.

HM series
3-phase 200 VAC -15% to 240 VAC +10% 47 to 63 Hz, 2.45 kVA
Single phase 230 VAC -10% to 240 VAC +10% 47 to 63 Hz, 2.45 kVA
HS series
3-phase 200 VAC -15% to 240 VAC +10% 47 to 63 Hz, 1.8 kVA
Single phase 230 VAC -10% to 240 VAC +10% 47 to 63 Hz, 1.8 kVA
HSA1 series
3-phase 200 VAC -15% to 240 VAC +10% 47 to 63 Hz, 1.69 kVA
Single phase 230 VAC -10% to 240 VAC +10% 47 to 63 Hz, 1.69 kVA
HSR series
3-phase 200 VAC -15% to 240 VAC +10% 47 to 63 Hz, 1.8 kVA
Single phase 230 VAC -10% to 240 VAC +10% 47 to 63 Hz, 1.8 kVA
XR series
3-phase 200 VAC -15% to 240 VAC +10% 47 to 63 Hz, 1.85 kVA
Single phase 230 VAC -10% to 240 VAC +10% 47 to 63 Hz, 1.85 kVA
SC series
3-phase 200 VAC -15% to 240 VAC +10% 47 to 63 Hz, 1.5 kVA
Single phase 230 VAC -10% to 240 VAC +10% 47 to 63 Hz, 1.5 kVA
I/O power supply Use external power supply Supply 24VDC +/-10% from outside
Use internal power supply Supply 24VDC +/-10% from inside controller
Short Circuit Current Rating(SCCR)

Other than UL-listed model: 5 kA

UL-listed model: 10 kA

Safety performance (*5) Structure : Category 4

Performance Level : e

MTTFD : 163.2 years

DCavg : 99%

PFHD : 1.50×10^-8/h

* Please specify the safety-I/O-less version in the case that safety I/O mounted on the standard version is not necessary

Stop category Category 1 (except Safety-I/O-less type.)
(See IEC 60204-1 for details of stop category)
Safety Functions

Comply with IEC 61508 (except Safety-I/O-less type.)

For a third-party certifier, refer to this(PDF:692KB).

IP code Top plate : IP3X
Other surfaces : IP20
IP54 when using protective box (optional)
Stand for vertical setup Note) Set right side (power connector side) down
External dimension

【Models except UL-Listed ones】

Standard, Safety I/O–less: W 356.5 x D 319.6 x H 96.8 [mm] 11.1 L

Safety motion : W 410.3 x D 319.6 x H 96.8 [mm] 12.7 L

【UL-Listed models】

Standard, Safety motion : W 410.3 x D 420 x H 130 [mm] 19.8L

* Except for the projection part.

Weight

【Models except UL-Listed ones】

Standard, Safety I/O–less : approximately 10 kg
Safety motion : approximately 11 kg

【UL-Listed models】

Standard, Safety motion : approximately 16 kg

To ensure safety functions, reboot the robot controller once in every 24 hours.

*1 : Expansion boards used in the RC7 robot controller cannot be used.

*2 : Pollution degree 2 is equivalent to household and office environment.

When using in a factory, take either of the following measures.

・ Put it into the control panel corresponding to pollution degree 3.

・ Use the controller protective box (optional).

*3 : Corresponding power distribution systems are as follows.

 TT, TN, IT

*4 : If the power supply can be dropped 95 V or less, such as in the heavily loaded facilities, using a transformer describes below is recommended. However, operation with 85 V or lower voltage is not guaranteed.

Transformer specification

Input voltage : 1Ph 100 V

Output voltage : 1Ph 200 V

Capacity : 1 kVA

*5 : This safety performance is determined for the robot stop functions; such as an emergency stop, enable auto, protective stop and deadman switch.
However, customer-prepared input devices, which connect to signals for emergency stop, Enable Auto, and protective stop, are not included in the safety performance calculation.

Calculation conditions

· This calculation is based on ISO 13849-1:2015.

· Expected operation counts a year (Nop) are as follows.

Operation Mission time (year)
10 20
Start/Stop (Motor ON/OFF) 38,933 19,466
Enable (Deadman) switch 10,000 5,000