<< Prev        Next >>

ID : 2703

IPC Set for RC8 Extension Function

Product Information

IPC set for RC8 extension function should be used in the installation environment with the following conditions.

Item Conditions
Name IPC set for RC8 extension function
Dimensions (D × H × W) 81.9 mm × 96mm × 65.9 mm (Outline drawing)
Supply voltage 22 - 30V (power supply unit: 24VDC)
Weight Without mounting sheet: approximately 550g
With mounting sheet: approximately 610g
Power consumption 14W
Basic configuration
  • 2 × RJ-45 Ethernet 100/1000BASE-T
  • 1 × Display-Port
  • 1 × USB 3.0
  • 1 × USB 2.0
Degree of protection IP20
(Use in the control box.)
Shock resistance

Sinusoidal vibration (EN 60068-2-6)

10 to 58 Hz: 0.035 mm
58 to 500 Hz: 0.5 G (approximately 5 m/s2)

Shock (EN 60068-2-27)

5G (approximately 50 m/s2) duration: 30 ms

EMC compatibility
  • Resistance to interference conforms to EN 61000-6-2
  • Emission of interference conforms to EN 61000-6-4
Ambient temperature
  • During operation: 0 to 55℃
  • During storage and transportation: -25 to 65℃
  • If you use it out of the above range, please contact our sales representatives.
Relative humidity 95 % or less (no dew condensation allowed)
Transport and storage The same values for atmospheric humidity and shock resistance are to be observed during transport and storage as in operation. Suitable packaging of the Industrial PC can improve the resistance to impact during transport.
Certifications CE

Connector Panel

Power supply
Connector that supplies power.
LAN1 / LAN2
Connector for network connection. This is used for connecting the EtherNet cable.
DisplayPort
This is used when transferring the video signal.
USB2.0 output
This is used for connecting peripheral devices with USB. (USB2.0 standard is supported.)
USB3.0 output
This is used for connecting peripheral devices with USB. (USB3.0 standard is supported.)

Status LEDs

IPC set for RC8 extension function equips the LED that displays the status.

For the way of displaying the LED corresponding to status of IPC set for RC8 extension function, see the table below.

Status LED Display color Status
HDD (Hard disk) Red Access to the memory device
TC (TwinCAT) Red TwinCAT Stop
Blue Config (setting mode)
Blue / Red blinking Config(Fieldbus Error)
Green Run (operation mode)
Green / Red blinking Run (Fieldbus Error)
PWR (Power) Green Industrial PC In operation
Yellow Shutdown

Consideration for Disposal

IPC set for RC8 extension function contains a lithium primary battery. Precautions are required for the handling, disposal, and recycling of batteries. For details, refer to “Consideration for Disposal”.

For information about how to remove the battery, refer to "How to Replace the Battery of IPC set for RC8 extension function".

ID : 2703

<< Prev        Next >>