ID : 2703
IPC Set for RC8 Extension Function
Product Information
IPC set for RC8 extension function should be used in the installation environment with the following conditions.
Item | Conditions |
---|---|
Name | IPC set for RC8 extension function |
Dimensions (D × H × W) | 81.9 mm × 96mm × 65.9 mm (Outline drawing) |
Supply voltage | 22 - 30V (power supply unit: 24VDC) |
Weight | Without mounting sheet: approximately 550g With mounting sheet: approximately 610g |
Power consumption | 14W |
Basic configuration |
|
Degree of protection | IP20 (Use in the control box.) |
Shock resistance |
Sinusoidal vibration (EN 60068-2-6)
10 to 58 Hz: 0.035 mm Shock (EN 60068-2-27)5G (approximately 50 m/s2) duration: 30 ms |
EMC compatibility |
|
Ambient temperature |
|
Relative humidity | 95 % or less (no dew condensation allowed) |
Transport and storage | The same values for atmospheric humidity and shock resistance are to be observed during transport and storage as in operation. Suitable packaging of the Industrial PC can improve the resistance to impact during transport. |
Certifications | CE |
Connector Panel
- Power supply
- Connector that supplies power.
- LAN1 / LAN2
- Connector for network connection. This is used for connecting the EtherNet cable.
- DisplayPort
- This is used when transferring the video signal.
- USB2.0 output
- This is used for connecting peripheral devices with USB. (USB2.0 standard is supported.)
- USB3.0 output
- This is used for connecting peripheral devices with USB. (USB3.0 standard is supported.)
Status LEDs
IPC set for RC8 extension function equips the LED that displays the status.
For the way of displaying the LED corresponding to status of IPC set for RC8 extension function, see the table below.
Status LED | Display color | Status | |
---|---|---|---|
HDD (Hard disk) | Red | Access to the memory device | |
TC (TwinCAT) | Red | TwinCAT | Stop |
Blue | Config (setting mode) |
||
Blue / Red blinking | Config(Fieldbus Error) | ||
Green | Run (operation mode) | ||
Green / Red blinking | Run (Fieldbus Error) | ||
PWR (Power) | Green | Industrial PC | In operation |
Yellow | Shutdown |
Consideration for Disposal
IPC set for RC8 extension function contains a lithium primary battery. Precautions are required for the handling, disposal, and recycling of batteries. For details, refer to “Consideration for Disposal”.
For information about how to remove the battery, refer to "How to Replace the Battery of IPC set for RC8 extension function".