<< Prev        Next >>

ID : 3039

Quarterly Inspections

Just after the robot has stopped, some parts of the robot might be hot. When touching the robot for its maintenance or carrying, be sure to wait until get it cold.

Check Items and Lubrication

Check the items listed below every three months.

Quarterly Inspections Table

No. Check: Controller Power How to check: Criterion What to do:
1 Robot base mounting bolts OFF Measure the tightening torque with a torque wrench.

No looseness.

Specified torque:

70 ±14 Nm

Tighten the bolts to the specified torque.
2 Cooling fan filters in the robot controller OFF Visually No dust or dirt. Clean the cooling fan filters.

Cleaning the Cooling Fan Filters in the Robot Controller

For the cleaning procedures of the air intake filter, refer to the RC8 SERIES ROBOT CONTROLLER MANUAL, "Cleaning the Air Intake Filter".