Area Setting

Description of Buttons

A: Jump

Display a selected line number.

B: View all items

Switch between visible and invisible of the Detail settings, such as the detection interval or detected pose.

C: Smart View

Display lines which Smart checkbox are selected.

D: Easy setting

Display [Easy setting window] of the area coordinates.

The result of the Easy setting will be given in the area coordinate of the selected number.

Easy Setting

Set an area coordinate by using teaching-completed P-type position variables.

Once an area coordinate is calculated from specified P-type variables, the result will be displayed in the Calculated area coordinate. Pressing [OK] will register the result into the called area number.

A: Point

Specify a teaching-completed P-type variable number that you want to use for the calculation.

B: Calculated area coordinate

Once an area coordinate is calculated from Point, the result will be displayed in the text boxes, and then [OK] button will be enabled.

C: [OK] button

Set the calculation result displayed in the Calculated area coordinate to the area coordinate.