ID : 7832
MC_ReadDIByte
To read an I/O input signal status of robot controller. (Byte)
Graphic expression | FB category | |
---|---|---|
Ver.5.5 | Ver.5.35 | |
Non motion |
Input and Output Variable
Variable name | Data type | Valid range | Default | Omission (*) |
---|---|---|---|---|
AxesGroup | eRC_AxesGroup | No | ||
|
Input Variable
Variable name | Data type | Valid range | Default | Omission (*) |
---|---|---|---|---|
Execute | Boolean |
|
FALSE | No |
|
||||
IoType | Integer | 0, 1 | 0 | No |
|
||||
IoByteNo | Integer |
|
0 | No |
|
(*) : For some Variable, entries can be omitted.
- Yes : Entry can be omitted.
- No : Entry required always.
Output Variable
Variable name | Data type / Description |
---|---|
Done | Boolean |
|
|
Busy | Boolean |
|
|
Error | Boolean |
|
|
ErrorID | Word |
|
|
ErrorIDEx | DWord |
|
|
Value | Byte |
|
Function Description
This function block reads an I/O input signal status of robot controller.
The following tables show the correspondence between robot controller port number and byte number.
- Hand I/O
IoByteNo Robot controller port number Robot controller I/O name 0 48 Hand input 49 Hand input 50 Hand input 51 Hand input 52 Hand input 53 Hand input 54 Hand input 55 Hand input - Mini I/O
IoByteNo Robot controller port number Robot controller I/O name 0 0 User input 1 User input 2 User input 3 User input 4 User input 5 User input 6 User input 7 User input 1 8 User input 9 User input 10 User input 11 User input 12 User input 13 User input 14 User input 15 User input