Input Data (Standard Allocation)

Port No. Description
512 Step Stop (All tasks)
513 -
514 Instantaneus stop (All tasks)
515 Strobe signal
516 Interruption skip
517 -
518 -
519 Command data area odd parity
520 Data area 1 bit 0
521 Data area 1 bit 1
522 Data area 1 bit 2
523 Data area 1 bit 3
524 Data area 1 bit 4
525 Data area 1 bit 5
526 Data area 1 bit 6
527 Data area 1 bit 7
528 Data area 2 bit 0
529 Data area 2 bit 1
530 Data area 2 bit 2
531 Data area 2 bit 3
532 Data area 2 bit 4
533 Data area 2 bit 5
534 Data area 2 bit 6
535 Data area 2 bit 7
536 Data area 2 bit 8
537 Data area 2 bit 9
538 Data area 2 bit 10
539 Data area 2 bit 11
540 Data area 2 bit 12
541 Data area 2 bit 13
542 Data area 2 bit 14
543 Data area 2 bit 15
544 Command area bit 0
545 Command area bit 1
546 Command area bit 2
547 Command area bit 3
548 -
549 -
550 -
551 -
552 User input (*1)
:
767
4096 User input (*1)
:
7871
11648 User input (*1)
:
15807

*1 : The range of available I/O port numbers differs depending on the input size setting. As a default setting, the user input ranges from 552 through 767 (input size: 32 [byte]). If the input size is 33 [byte] or larger, user inputs are allocated to 552-767, 4096-7871. For example, if the input size is 33 [byte], the user inputs are allocated to 552-767, 4096-4103.