ID : 58
5th-axis CALSET position (VS-050/060)
Determine the CALSET position of the 5th axis of the VS-050/060 using the 4th-axis CALSET bolt.
Set the 4th-axis CALSET bolt in the position shown below and then gently press the 5th axis against the negative-direction end by hand. (The 4th-axis CALSET bolt is stored in the encoder backup battery box. Refer to "Encoder Backup Battery Box".)
ID : 58