ID : 843
Solenoid Valve Specifications (VM series)
Solenoid valve specifications of VM series are common.
Item | Specifications | |
---|---|---|
Valve |
Switching system | 2-position double |
Applicable fluid | Air | |
Operating system | Pilot type | |
Effective cross section (Cv value) | P®A/B:1.98mm²(0.11) A/B®R:1.80mm²(0.10) |
|
Lubrication | Oilless | |
Operating pressure range | 0.1 to 0.7 MPa (Note 1) | |
Response time | 10 ms or less (at 0.5 MPa) | |
Maximum operating frequency | 10 Hz | |
Ambient temperature | -5 to 50°C (No dew condensation allowed. When dry air is used) | |
Solenoid |
Operating voltage | 24 V ±10% |
Power consumption (current) | 0.65 W (27 mA) | |
Surge voltage protection circuit | Diode |
Note 1:The air source connected to the robot unit must be used within the operating pressure range from 0.05 to 0.35 MPa (refer to "Robot Specifications ").
Pneumatic Circuit
When both solenoids A and B are deenergized, the valve holds its position.
A, B | Air outlet to tools |
---|---|
P | Air inlet from AIR1 |
EA, EB | To exhaust ports For clean room type, these are connected to “VALVE-OUT” (AIR2) of a connector panel. |
The Valve Exhaust Port
Do not cover the valve exhaust port behind the second arm.
ID : 843