<< Prev        Next >>

ID : 5498

Specifications

The table below lists the specifications of the controller protective box.

Item Specifications
Applicable controller RC8 series robot controller (The controller equipped with an I/O conversion box is also applicable.) *2
Environmental conditions (Temperature and humidity) In operation 0 to 40 ℃, 20 to 90% RH (dew condensation not allowed)
In storage or during transportation -10 to 60 ℃, 40 to 75% RH (dew condensation not allowed)
Enclosure Equivalent to IP54
Installation Type Stand-alone Installation *3
Weight (Mass) Approx. 26 kg (RC8 series robot controller is not included)
Power supply *1 Three-phase AC185-253 V(AC200 V-7 %~AC230 V+10 %)
Single-phase AC207-253 V(AC230 V±10 %)
Heat exchanger Fans Internal fan and external fan
External fan: 4715HS-23W-B50-AM0 (Manufactured by Minebea Co.,Ltd)
Internal fan : 4715MS-23W-B50-A00 (Manufactured by Minebea Co.,Ltd)
Cooling power 35 W/K (temperature change 1 ℃ , calculated value)
Power supply Supplied from the controller power and branched by the protective box-incorporated terminal.
Power supply capacity: 0.15KVA

*1: The power supply of the controller protective box, unlike that of the controller.

*2: Not contained in UL-Listed controller.

*3: Do not place the controller vertically.