SysLog.Trace.Stop

Function

To finish trace log recording.

Syntax

SysLog.Trace.Stop

Description

This command stops recording the log. The recording in the ring buffer ends at this command.
You can obtain the log data that ranges from the start-timing specified by the parameter to this command, or that ranges from the STARTLOG command (SysLog.Trace.Start) to this command.

For details, refer to "Recording by Program Commands" in "Logging" in Basic of Robot Motion Creation.

Attention

  • See "Displaying the Trace Log" in "Smart TP Operation Guide" for about how to check the trace log with a Smart TP.
  • See Acquisition of Log Data in "WINCAPSIII GUIDE" for about how to export controller's log data to WINCAPSIII.
    See "Displaying and Reading Project List" in "Smart TP Operation Guide" for about how to export controller's log data to a USB.

Example

Sub Main 
	SysLog.Trace.Clear
	SysLog.Trace.Start
	
	TakeArm
	Motor On
	ExtSpeed 50
	Speed 100
	
	Move P, P1
	Move P, P2
	Move P, P3
	
	SysLog.Trace.Stop 
End Sub