ID : 7943
Input Data (Standard Allocation)
Port No. | Description |
---|---|
512 | Step Stop (All tasks) |
513 | - |
514 | Instantaneus stop (All tasks) |
515 | Strobe signal |
516 | Interruption skip |
517 | - |
518 | - |
519 | Command data area odd parity |
520 | Data area 1 bit 0 |
521 | Data area 1 bit 1 |
522 | Data area 1 bit 2 |
523 | Data area 1 bit 3 |
524 | Data area 1 bit 4 |
525 | Data area 1 bit 5 |
526 | Data area 1 bit 6 |
527 | Data area 1 bit 7 |
528 | Data area 2 bit 0 |
529 | Data area 2 bit 1 |
530 | Data area 2 bit 2 |
531 | Data area 2 bit 3 |
532 | Data area 2 bit 4 |
533 | Data area 2 bit 5 |
534 | Data area 2 bit 6 |
535 | Data area 2 bit 7 |
536 | Data area 2 bit 8 |
537 | Data area 2 bit 9 |
538 | Data area 2 bit 10 |
539 | Data area 2 bit 11 |
540 | Data area 2 bit 12 |
541 | Data area 2 bit 13 |
542 | Data area 2 bit 14 |
543 | Data area 2 bit 15 |
544 | Command area bit 0 |
545 | Command area bit 1 |
546 | Command area bit 2 |
547 | Command area bit 3 |
548 | - |
549 | - |
550 | - |
551 | - |
552 | User input (*1) |
: | |
767 | |
4096 | User input (*1) |
: | |
5887 |
*1 : The range of available I/O port numbers differs depending on the input size setting. As a default setting, the user input ranges from 552 through 767 (input size: 32 [byte]). If the input size is 33 [byte] or larger, user inputs are allocated to 552-767, 4096-7871. For example, if the input size is 33 [byte], the user inputs are allocated to 552 to 767, 4096 to 4103.
ID : 7943