ID : 172
CurExtDec
Function
To return the current setting value of external deceleration.
Syntax
CurExtDec
Return Value
Return the current setting value (0-100) of external deceleration by Single Precision Real Number Type data.
Description
The current setting value of external deceleration is returned.
Related Terms
Speed, Accel, Decel, ExtSpeed, ExtAccel, ExtDecel, CurSpd, CurAcc, CurDec, CurExtSpd, CurExtAcc
Attention
-
Example
'!TITLE "Acquiring External Deceleration"
' Acquire the currently external deceleration setting
Sub CurExtDec_Sample
Dim aaa As Single
TakeArm Keep = 1
' Set external deceleration to 50% of the current value
Decel CurExtAcc * 0.5
' Assign the current external deceleration to aaa
aaa = CurExtDec
' Display external deceleration on the message output window
PrintDbg aaa
End Sub
ID : 172