ID : 959
Quarterly Inspections
Check Items
Check the items listed in the table below every three months.
No. | Check: | Controller Power | How to check: | Criterion | What to do: |
---|---|---|---|---|---|
1 | Robot base mounting bolts | OFF | Measure the tightening torque with a torque wrench. | No looseness. Specified torque: 35 ±7 Nm |
Tighten the bolts to the specified torque. |
2 | Cooling fan filters in the robot controller | OFF | Visually | No dust or dirt. | Clean the cooling fan filters. |
Cleaning the Air Intake Filter in the Robot Controller
For the cleaning procedures of the air intake filter, refer to the RC8 SERIES ROBOT CONTROLLER MANUAL, "Cleaning Intake Port Filter".
ID : 959