ID : 1317
Specification of RC8 Controller
Term | Specification | |
---|---|---|
Applicable robot | VM-6083 / VM-60B1 VS-6556 / VS-6577 VS050 / VS060 / VS068 / VS087 VP-6242 / VP-5243 HM series / HS series XR series / SC series |
|
Type | RC8-****-****-**-*** | |
Number of axes controlled | Robot : 4 to 6 axes Extended-joint : 2 to 4 axes (optional) |
|
Control method | PTP, CP 3-dimensional linear, 3-dimensional arc |
|
Drive method | All axes all digital AC servo | |
Language in use | DENSO Robotics language (PacScript) | |
Memory capacity | User area Variable area : 1.75 Mbyte (32,766 points equivalent), file area : 400 Mbyte (5,000 steps x 256 files) | |
Teaching method |
|
|
External signal (I/O, etc.) |
Mini I/O | Input : User open 8 points + System fix 14 points |
Hand I/O | Input : 8 points Output : 8 points |
|
Safety I/O |
Input and output signals are integrated into Mini I/O connector. |
|
Parallel I/O board (optional) (*1) |
Expansion slot : PCI Input : 40 points Output : 48 points |
|
CC-Link remote device board (optional) (*1) |
Expansion slot : PCI Express Input : Up to 8192 points Output : Up to 8192 points Remote register Input : Up to 2048 words Output : Up to 2048 words |
|
DeviceNet slave board (optional) (*1) |
Expansion slot : PCI Express Input : Up to 256 points Output : Up to 256 points |
|
DeviceNet master board (optional) (*1) |
Expansion slot : PCI Express Input : 1024 points Output : 1024 points |
|
EtherNet/IP Adapter board (optional) (*1) |
Expansion slot : PCI Express Input : Up to 4032 points Output : Up to 4032 points |
|
PROFIBUS slave board (optional) (*1) |
Expansion slot : PCI Express Input : Up to 256 points Output : Up to 256 points |
|
PROFINET IO Device board (optional) |
Expansion slot : PCI Express Input : Up to 8192 points Output : Up to 8192 points |
|
EtherCAT slave board (optional) |
Expansion slot : PCI Express Input : Up to 2048 points Output : Up to 2048 points |
|
RS232C expansion board (optional, not supplied) |
DENSO supplies software only and board is not supplied. | |
External communication | RS232C | 1 line |
Ethernet | 1 line (GbE : Gigabit Ethernet) | |
USB | 2 lines | |
VGA optional | 1 line | |
Electric gripper control board (optional) ( *1) |
Expansion slot : PCI | |
Expansion slot |
|
|
Self diagnosis function | Overrun, servo error, memory error, input error, short circuit detection (user wiring part), etc. | |
Timer function | 0.02 to 10 sec. (1/60 sec. step) | |
Error display |
|
|
Cable | Motor & encoder cable for RC8series (optional) |
2m, 4m, 6m, 12m, 20m Note) Motor connector x 3, encoder connector x 1 |
I/O cable (optional) |
8m, 15m (for Mini I/O, for Hand I/O, for expansion parallel I/O) |
|
RC8 series power cable | 5m | |
For RC8 series Extended-joint motor cable (optional) |
2m, 4m, 6m, 12m (standard version) |
|
For RC8 series Extended-joint encoder cable (optional) |
1m, 2m, 4m, 6m, 12m (standard version) |
|
External operation device | Teach pendant (optional) |
4m, 8m, 12m |
Mini-pendant (optional) |
4m, 8m, 12m | |
Emergency stop switch box (optional) |
4m | |
Pendant extension cable (optional) |
4m, 8m (Available for Emergency stop switch box as well) |
|
Environmental condition (in motion) | Temperature 0 to 40 degree C, humidity 20 to 90% RH (No dew condensation allowed.) | |
Defacement (pollution) degree | 2 (*2) | |
Power supply | VM 3-phase 200 VAC -15% to 240 VAC +10% 47 to 63 Hz, +3.3 kVA |
|
VS-6556/6577 3-phase 200 VAC -15% to 240 VAC +10% 47 to 63 Hz, 1.8 kVA Single phase 230 VAC -10% to 240 VAC +10% 47 to 63 Hz, 1.8 kVA |
||
VS-050/060 3-phase 200 VAC -15% to 240 VAC +10% 47 to 63 Hz, 1.15 kVA Single phase 230 VAC -10% to 240 VAC +10% 47 to 63 Hz, 1.15 kVA |
||
VS-068/087 3-phase 200 VAC -15% to 240 VAC +10% 47 to 63 Hz, 2.78 kVA Single phase 230 VAC -10% to 240 VAC +10% 47 to 63 Hz, 2.78 kVA |
||
VP 3-phase 200 VAC -15% to 240 VAC +10% 47 to 63 Hz, 1.0 kVA Single phase 230 VAC -10% to 240 VAC +10% 47 to 63 Hz, 1.0 kVA 100V version AC100 V -5 % to AC110 V +10% 47 to 63 Hz, 1.0 kVA (*2) |
||
HM series 3-phase 200 VAC -15% to 240 VAC +10% 47 to 63 Hz, 2.45 kVA Single phase 230 VAC -10% to 240 VAC +10% 47 to 63 Hz, 2.45 kVA |
||
HS series 3-phase 200 VAC -15% to 240 VAC +10% 47 to 63 Hz, 1.8 kVA Single phase 230 VAC -10% to 240 VAC +10% 47 to 63 Hz, 1.8 kVA |
||
XR series 3-phase 200 VAC -15% to 240 VAC +10% 47 to 63 Hz, 1.85 kVA Single phase 230 VAC -10% to 240 VAC +10% 47 to 63 Hz, 1.85 kVA |
||
SC series |
||
I/O power supply | Use external power supply | Supply 24VDC +/-10% from outside |
Use internal power supply | Supply 24VDC +/-10% from inside controller | |
SCCR | Other than UL-listed model: 5KA UL-listed model: 10KA |
|
Safety performance (*4) | Structure : Category 4 Performance Level : e MTTFd : 100 years DCavg : 99 % PFHd : 7.42×10-8 * Please specify the safety-I/O-less version in the case that safety I/O mounted on the standard version is not necessary |
|
Stop category | Category1 (except Safety-I/O-less type.) (See IEC60204-1 for details of stop category) |
|
IP code | IP20 IP54 when using protective box (optional) |
|
Stand for vertical setup | Note) Set right side (power connector side) down | |
External dimension | Standard : W 440.5 x D 299.6 x H 96.6 [mm] 12.8 L * Except for the projection part. |
|
Weight | Standard : approximately 12 kg UL : approximately 18 kg |
*1 : Expansion boards used in the RC7 robot controller cannot be used.
*2 : Pollution degree 2 is equivalent to household and office environment.
When using in a factory, take either of the following measures.
・ Put it into the control panel corresponding to pollution degree 3.
・ Use the controller protective box (optional).
*3 : If the power supply can be dropped 95 V or less, such as in the heavily loaded facilities, using a transformer describes below is recommended. However, operation with 85 V or lower voltage is not guaranteed.
- Transformer specification
-
Input voltage : 1Ph 100 V
Output voltage : 1Ph 200 V
Capacity : 1 kVA
*4 : This safety performance is determined for the robot stop functions; such as an emergency stop, enable auto, protective stop and deadman switch.
However, customer-prepared input devices, which connect to signals for emergency stop, Enable Auto, and protective stop, are not included in the safety performance calculation.
- Calculation conditions
-
· This calculation is based on ISO 13849-1:2006.
· Expected operation counts a year (Nop) are as follows.
Operation Mission time (year) 10 20 Start/Stop (Motor ON/OFF) 136,986 68,493 Enable (Deadman) switch 10,000 5,000
ID : 1317