ID : 1370
[NPN type, Mini I/O dedicated mode] Mini I/O Pin Assignment for RC8
The table below lists the pin assignment of Mini I/O (NPN type) in Mini I/O dedicated mode.
View from the cable side |
|||||||
Terminal No. (*1) | Signal name | Port No. | Wire color | Terminal No. (*1) | Signal name | Port No. | Wire color |
---|---|---|---|---|---|---|---|
1 | Enable Auto1, -1 (input) | - | Black | 35 | Enable Auto1, -2 (input) | - | Pink |
2 | External Emergency Stop 1, b-1 (input) | - | Brown | 36 | External Emergency Stop 1, b-2 (input) | - | Pink |
3 | External Emergency Stop 2, b-1 (input) | - | Red | 37 | External Emergency Stop 2, b-2 (input) | - | Pink |
4 (*2) | Protective Stop 1, -1 (input) | - | Orange | 38 (*2) | Protective Stop 1, -2 (input) | - | Pink |
5 (*2) | Protective Stop 2, -1 (input) | - | Yellow | 39 (*2) | Protective Stop 2, -2 (input) | - | Pink |
6 | Contactor Contact Monitor 1 ,b-1 (out put) | - | Black | 40 | Contactor Contact Monitor 1, b-2 (out put) | - | White |
7 | Contactor Contact Monitor 2, b-1 (out put) | - | Brown | 41 | Contactor Contact Monitor 2, b-2 (out put) | - | White |
8 | Deadman SW 1, -1 (output) [Enable SW 1, -1] |
- | Red | 42 | Deadman SW 1, -2 (output) [Enable SW 1, -2] |
- | White |
9 | Deadman SW 2, -1 (output) [Enable SW 2, -1] |
- | Orange | 43 | Deadman SW 2, -2 (output) [Enable SW 2, -2] |
- | White |
10 | Contactor Contact Monitor 1, a-1 (out put) | - | Yellow | 44 | Contactor Contact Monitor 1, a-2 (out put) | - | White |
11 | Step Stop (All tasks) (System input) | 0 | Green | 45 | CPU Normal (System output) | 16 | White |
12 | Strobe Signal (System input) | 1 | Blue | 46 | Robot Running (System output) | 17 | White |
13 | Data area bit 0 (System input) | 2 | Violet | 47 | Robot Error (System output) | 18 | White |
14 | Data area bit 1 (System input) | 3 | Gray | 48 | Robot Initialized (System output) | 19 | White |
15 | Data area bit 2 (System input) | 4 | Pink | 49 | Auto Mode (System output) | 20 | White |
16 | Command area bit 0 (System input) | 5 | Black | 50 | Operation Preparation Completed (System output) | 21 | Gray |
17 | Command area bit 1 (System input) | 6 | Black | 51 | Battery Warning (System output) | 22 | Violet |
18 | Command area bit 2 (System input) | 7 | Brown | 52 | Command Processing Completed (System output) | 23 | Violet |
19 | User input | 8 | Red | 53 (*3) | User output / Continue Start Permission (System output) | 24 | Violet |
20 | User input | 9 | Orange | 54 | User output | 25 | Violet |
21 | User input | 10 | Yellow | 55 | User output | 26 | Violet |
22 | User input | 11 | Green | 56 | User output | 27 | Violet |
23 | User input | 12 | Blue | 57 | User output | 28 | Violet |
24 | User input | 13 | Gray | 58 | User output | 29 | Violet |
25 | User input | 14 | Pink | 59 | User output | 30 | Violet |
26 | User input | 15 | Brown | 60 | User output | 31 | Gray |
27 | Contactor Contact Monitor 2 ,a-1 (out put) | - | Red | 61 | Contactor Contact Monitor 2 ,a-2 (out put) | - | Gray |
28 | Pendant Emergency Stop 1, b-1 (output) (Dry output) |
- | Orange | 62 | Pendant Emergency Stop 1, b-2 (output) (Dry output) | - | Gray |
29 | Pendant Emergency Stop 2, b-1 (output) (Dry output) |
- | Yellow | 63 | Pendant Emergency Stop 2, b-2 (output) (Dry output) |
- | Gray |
30 | Reserved. | - | Green | 64 | Reserved. | - | Gray |
31 | Enable Auto 2, -1 (input) | - | Blue | 65 | Enable Auto 2, -2 (input) | - | Gray |
32 |
DC power input +24V (when external power source is used) DC power output +24V (when internal power source is used) |
- | Pink | 66 |
DC power input 0V (when external power source is used) DC power output 0V (when internal power source is used) |
- | Gray |
33 | - | Black | 67 | - | Blue | ||
34 | - | Brown | 68 | - | Blue |
*1 : The optional I/O cable for the above connector consists of twisted pair wires--pairs of #1 and #35, #2 and #36, #34 and #68.
*2 : If no Protective Stop input signals are needed, short-circuit by terminal connection with jumpers between #4 and #38 and between terminals #5 and #39.
*3 : This item differs depending on "User or System output setting" of I/O parameters. Default setting is user output.
The reserved pins and output pins should be prevented from direct contact with other pins or conductive part. Direct contact could result in a controller failure or damage.