<< Prev        

ID : 5590

32bit Error Code Output

Function

This signal outputs an error code converted from hexadecimal of eight figures into the binary of 32 figures.
" 1" represents ON, "0" represents OFF.
"Error number output" of the system output outputs an error code that has been converted into a RC7M error code. However, this function outputs the original error code of RC8 series.

Usage

This signal is used to use a RC8 series original error number in the external devices.
The port number which has been designated by the"32bit Error Code Output IO No"is set to the lowest bit.

ON Condition

When an error of level 1 or higher has been issued, this signal converts the error number into a binary digit, and then turns ON the port of "1".

RC3 Compatible allocation Turn ON when an error occurs.
Standard allocation Turn ON when an I/O command "Error Read" is executed.

OFF Condition

This signal is OFF when an error of level 1 or higher has not been issued.
To turn OFF this signal after an error occurrence, clear the error.

Timing Chart

ID : 5590

<< Prev