ID : 7647
MC_ReadDOBit
To read an I/O output signal status of robot controller. (Bit)
Graphic expression | FB category |
---|---|
Non motion |
Input and Output Variable
Variable name | Data type | Valid range | Default | Omission (*) |
---|---|---|---|---|
AxesGroup | eRC_AxesGroup | No | ||
|
Input Variable
Variable name | Data type | Valid range | Default | Omission (*) |
---|---|---|---|---|
Execute | Boolean |
|
FALSE | No |
|
||||
IoType | Integer | 0, 1 | 0 | No |
|
||||
IoBitNo | Integer |
|
0 | No |
|
(*) : For some Variable, entries can be omitted.
- Yes : Entry can be omitted.
- No : Entry required always.
Output Variable
Variable name | Data type / Description |
---|---|
Done | Boolean |
|
|
Busy | Boolean |
|
|
Error | Boolean |
|
|
ErrorID | Word |
|
|
ErrorIDEx | DWord |
|
|
Value | Boolean |
|
Function Description
This function block reads an I/O output signal status of robot controller.
The following tables show the correspondence between robot controller port number and bit number.
- Hand I/O
IoBitNo Robot controller port number Robot controller I/O name 0 64 Hand output 1 65 Hand output 2 66 Hand output 3 67 Hand output 4 68 Hand output 5 69 Hand output 6 70 Hand output 7
71 Hand output - Mini I/O
IoBitNo Robot controller port number Robot controller I/O name 0 16 CPU Normal 1 17 User output 2 18 User output 3 19 User output 4 20 User output 5 21 User output 6 22 User output 7
23 User output 8 24 User output 9 25 User output 10 26 User output 11 27 User output 12 28 User output 13 29 User output 14 30 User output 15 31 User output
Attention
-
ID : 7647