ID : 7648
MC_ReadDOByte
To read an I/O output signal status of robot controller. (Byte)
Graphic expression | FB category |
---|---|
Non motion |
Input and Output Variable
Variable name | Data type | Valid range | Default | Omission (*) |
---|---|---|---|---|
AxesGroup | eRC_AxesGroup | No | ||
|
Input Variable
Variable name | Data type | Valid range | Default | Omission (*) |
---|---|---|---|---|
Execute | Boolean |
|
FALSE | No |
|
||||
IoType | Integer | 0, 1 | 0 | No |
|
||||
IoByteNo | Integer |
|
0 | No |
|
(*) : For some Variable, entries can be omitted.
- Yes : Entry can be omitted.
- No : Entry required always.
Output Variable
Variable name | Data type / Description |
---|---|
Done | Boolean |
|
|
Busy | Boolean |
|
|
Error | Boolean |
|
|
ErrorID | Word |
|
|
ErrorIDEx | DWord |
|
|
Value | Byte |
|
Function Description
This function block reads an I/O output signal status of robot controller.
The following tables show the correspondence between robot controller port number and byte number.
- Hand I/O
IoByteNo Robot controller port number Robot controller I/O name 0 64 Hand output 65 Hand output 66 Hand output 67 Hand output 68 Hand output 69 Hand output 70 Hand output 71 Hand output - Mini I/O
IoByteNo Robot controller port number Robot controller I/O name 0 16 CPU Normal 17 User output 18 User output 19 User output 20 User output 21 User output 22 User output 23 User output 1 24 User output 25 User output 26 User output 27 User output 28 User output 29 User output 30 User output 31 User output
Attention
-
ID : 7648