ID : 1840
Reconfiguring I/O Signals
Key
[I/O] ([SHIFT] + [STEP START])
I/O Port and I/O Allocation
Symbols of I/O port and I/O allocation listed below table are displayed on the mini-pendant.
I/O port | Symbol |
---|---|
User input | GI |
User output | GO |
System input | DI |
System output | DO |
Hand input | HI |
Hand output | HO |
Internal I/O | IT |
CC-Link system input area | SI |
CC-Link system output area | SO |
CC-Link remote register input area (RWw) | WI |
CC-Link remote register output area (RWr) | WO |
I/O allocation | Symbol |
---|---|
Selectable I/O | Selctbl |
DeviceNet master allocation | DVMastr |
Compatible allocation | Compati |
Standard allocation | Standrd |
Operation
1
Press [I/O] to call up the I/O signal truth table as shown below.
2
To change the truth status assigned to I/O lines, choose the line with the up, down, left, and right cursor keys.
3
Press [OK] call up the "Function" screen that handles I/O signals.
To return to the I/O signal truth table, press [CANCEL].
Choose one of handles with the up and down cursor keys, then press [OK].
4
JumpTo
If you choose "JumpTo" with the up and down cursor keys, the JumpTo screen appears. Enter an I/O line number you want to jump to, into the highlighted line and then press [OK].
To discard the new setting and return to the I/O signal truth table, press [CANCEL].
5
On/Off
If you choose "On/Off" with the up and down cursor keys and press [OK], then the following screen appears where you can reverse the truth assignment of the line.
To discard the new setting and return to the I/O signal truth table, press [CANCEL].
ID : 1840