ID : 2679
HM-4A85*-C5/HM-4AA0*-C5 (Clean Room Type)
Please refer to this if the figure is not clear.(PDF:426KB)
Note 2: Pins #1 to #24 on CN21 and those on CN20 are connected with each other. The allowable current per line is 1 A.
Note 3: Use the attached connector sets for CN20 and CN21.
Supply dry air filtered through an air filter (Recommended filtration rating: 5 µm or below). Before piping, blow the air tube out with dry air to clean out the inside (flushing); otherwise, any chips, cutting oil, dust or dirt remaining in the air tube may result in a damaged valve.
Connector set part No. | Part No. | Model and part name | External appearance |
|
---|---|---|---|---|
410889-010* | 410877-048* (CN20用) |
JL05-6A24-28S-(A72) (Japan Aviation Electronics Industry Ltd.) |
||
410877-049* (CN20用) |
JL05-24EB3B-(17)-(A72) (Japan Aviation Electronics Industry Ltd.) |
Applicable wire diameter |
||
410877-050* (CN20用) |
JL05-24EB3B-(21)-(A72) (Japan Aviation Electronics Industry Ltd.) |
Applicable wire diameter |
||
410877-047* (CN21用) |
EBSP2524A (DDK Electronics, Inc.) |
ID : 2679