Tool Menu

Description of the Drop-down Menu

DIO Command Viewer

This displays the DIO command viewer dialog box for displaying standard command patterns or those with mini I/O assignments. During debugging, this dialog box also allows batch setting of command patterns for dummy I/O.

Controller Extention

This menu allows to set DENSO robot option functions by using WINCAPSIII. This is available only in the online monitoring mode.

For the operation procedure, refer to “Registering License”.

RC8 Communication settings

From the WINCAPSIII, set the [Executable token setting], [IP setting], and [Data communication setting].

Do the following two steps.

This function is available in Ver.2.7.* or higher.

1

Enter the IP address of the target controller, and then click [Connect].

2

Enter the necessary items and click [Change setting].

  • Executable token setting

    From the Executable token pane, select the executable token of RC8.

  • IP setting

    Set the IP address of RC8.

Be sure to make a note of the IP address you entered.

  • Data communication setting

    Select a device. Change item values.

Simple Position Correction Function

When the robot moves from the set position, you can correct the following three items with WINCAPSIII.

  • CALSET
    When motors are replaced, overwrite the CALSET value with the proper value based on the reference position.
  • TOOL
    Correct TOOL values when a new tool coordinates has been determined or the tool end gets moved.
  • WORK
    When the installation position of the robot is changed, correct the WORK coordinates that has been set.

For details, refer to Simple position correction function of FUNCTION GUIDE.

RC8 Tools

Resets a login password for the robot controller.
For details, refer to “Resetting the Login Passwords”.

USB

This is for reading or writing project data from/to a USB memory.

Writing function is exclusive for the RC7M controller.

ARM-Parameter

Reads/writes arm parameters needed for controller settings.

Project Comparison

Compare the project which is currently opened by WINCAPSIII and controller data, and then display the list of the result in additional window.

Comparison Results

Make sure to establish communication between WINCAPSIII and the controller, because this function requires receiving data from the controller.

Re-Login

This returns to the dialog box for logging in, the only way to changing user levels while WINCAPSIII is running

Option

This displays the dialog box for configuring such software options as the editor's syntax highlighting colors and communications time out limits.

The following functions are exclusive functions for the RC7M controller and not available for the RC8 series robot controller.

  • Controller Extension

 