ID : 1323

Types of System I/O Signals

It issues PROGRAM START commands as I/O commands by using seven command execution inputs.

The table below lists the types of system I/O signals.

Fixed by System

Type No. of points Function
System input 7 External Emergency Stop 1, External Emergency Stop 2, Enable Auto 1, Enable Auto 2, Step Stop (All tasks), Protective Stop 1, Protective Stop 2
System output RC8A 18 (Note1) Auto Mode, Robot Initialized, Robot Running, CPU Normal, Robot Error, Operation Preparation Completed, Battery Warning, Pendant Emergency Stop 1, Pendant Emergency Stop 2, Deadman SW 1 [Enable SW 1], Deadman SW 2 [Enable SW 2], STO Monitor 1a, STO Monitor 2a, STO Monitor 1b, STO Monitor 2b, Continue Start Permission (selectable by I/O parameter) (Note1), Auto Mode 1 (safety output) (Note2), Auto Mode 2 (safety output) (Note2)
RC8 16 (Note1) Auto Mode, Robot Initialized, Robot Running, CPU Normal, Robot Error, Operation Preparation Completed, Battery Warning, Pendant Emergency Stop 1, Pendant Emergency Stop 2, Deadman SW 1 [Enable SW 1], Deadman SW 2 [Enable SW 2], Contactor Contact Monitor 1a, Contactor Contact Monitor 2a, Contactor Contact Monitor 1b, Contactor Contact Monitor 2b, Continue Start Permission (selectable by I/O parameter) (Note1)
Input for command execution 7 Command (3 bits), data area (3 bits), and Strobe Signal
Output for command execution 1 Command Processing Completed

Note1 : The terminal number 53 (port number 24) on Mini I/O is assigned to a user output at the factory default.
You can assign this terminal to a system output (Continue Start Permission output signal) by setting the I/O parameter of "23 : User or System output setting" to "1".

Note2 : Except for RC8A Safety I/O-less specification.

Controlled by User Program

Type No. of points Function
User input 8 Inputs to read the external I/O status with an IN command or IO [ ] variable. Used for analysis condition identification, condition satisfaction wait, data input from the external equipment, etc.
User output 7 (Note1) Outputs to issue a signal to the external equipment during program execution with SET and RESET commands, etc.
HAND input 8 Inputs to read the external I/O status with an IN command or IO [ ] variable. Used for checking the hand status.
HAND output 8

Outputs to issue signals to the external equipment with SET and RESET commands, etc.

Used for controlling the hand to open or close.

Note1 : The terminal number 53 (port number 24) on Mini I/O is assigned to a user output at the factory default.
You can assign this terminal to a system output (Continue Start Permission output signal) by setting the I/O parameter of "23 : User or System output setting" to "1".