Air Piping and Signal Wiring for Clean Room Type

The following image shows the Ethernet- and the External battery unit-equipped robot unit.

 

Please refer to this if the figure is not clear.(PDF:498KB)

Note 3: Pins #1 to #19 on CN21 and those on CN20 are connected with each other. The maximum rated current per line is 1A.

Note 4: Use the attached connector set for CN20 and CN21.

Supply dry air filtered through an air filter (Recommended filtration rating: 5 µm or below).
Before piping, blow the air tube out with dry air to clean out the inside (flushing); otherwise, any chips, cutting oil, dust or dirt remaining in the air tube may result in a damaged valve.

Connector set part No. Part No. Model and name Appearance
410889-098* 410877-101*
(for CN20)
CA-19S1N1280DNS (Phoenix)
410877-044*(*1)
(for CN21)
WEBSP2119M-1-D(R1)
(Straight plug)
(DDK Electronics, Inc.)

Applicable wire diameter φ10.5 to 14.1

- 410877-098*
(for Ethernet)
SACC-MS-8QO SH ETH SCO
(Phoenix)
410877-102*
(for Ethernet)
09 35 225 0401 (HARTING)

*1: The connector design was changed in May 2019. As these connectors are interchangeable, either connector can be used for robot connection. However, applicable wire diameter is different from the old and new models. If you use a new connector, select a cable that satisfies the applicable wire diameter listed in the above table.