<< Prev        Next >>

ID : 3343

Setting Method for Motion I/O Power Supply

Motion I/O power supply (+24 V DC) can be selected to be obtained either from external power or from internal power by teach pendant. Factory setting is set to external power supply.

Refer to the "Displaying and Changing I/O Parameters " of TEACH PENDANT OPERATION GUIDE.

  • When using external power supply, make sure that Motion I/O power supply is turned on before supplying the power to the controller.
  • Changing setting of Motion I/O power supply from external power to internal power changes terminal No. 32 to 34 and terminal No. 66 to 68 to the internal DC power source output from the external DC power input.
  • Power supply setting of Motion I/O will be the same as that of Mini I/O and Hand I/O. 
    You cannot set the power supply setting individually.

ID : 3343

<< Prev        Next >>